Rack Mounting Procedure
The unit can be mounted on optional rack systems, including:
z RSU 129: 9.5 inch deep, 1U rack shelf kit (part number 60-190-01)
z RSU 126: 6 inch deep, 1U rack shelf kit (part number 60-190-10)
To mount the device on a rack shelf
1. Remove the feet from the bottom of the MTP, if they are installed.
2. Mount the MTP using two 4-40 x 3/16 inch screws in opposite (diagonal) corners to
secure the MTP to the shelf.
NOTE: DO NOT stack units on top of one another as this may cause the units to
overheat.
3. Install false faceplates or other units to the rack shelf.
Use 2 mounting holes on
opposite corners.
(2) 4-40 x 3/16"
Screws
NOTE: Using scre
ws longer
than 3/16” will damage the
unit and void the warranty.
1U Universal Rack Shelf
Front false
faceplate
uses 2
screws.
1/2 Rack Width Front False
Faceplate
Figure 10. Mounting the MTP on a Standard Shelf
Under-desk Mounting
Mount the unit under a desk or podium, using the optional Extron MBU 125 under-desk
mounting kit (part number 70-077-01) by following the instructions provided with the kit.
Through-desk Mounting
Mount the unit through a desk or podium using the optional Extron MBD 129 through desk
mounting kit (part number 70-077-02) by following the instructions provided with the kit.
MTP 1500RL 15HD RS SEQ • Mounting 15