Transmission Distance
The maximum transmission distance is determined by the frequency and resolution of the
transmitted signal. The table below shows the maximum transmission distances (in feet and
meters) and the transmitter Pre-peak switch positions using Extron Enhanced Skew-Free AV
UTP cable or UTP CAT cable, terminated with RJ-45 connectors.
Transmission Distances in feet (meteres)
Video Format Pre-peak Off Pre-peak On Max Distance
Vid, S-vid, YUV <1300 (396) >1400 (427) 1500 (457)
640x480 <1300 (396) >1400 (427) 1500 (457)
800x600 <1300 (396) >1400 (427) 1500 (457)
1024x768 <1300 (396) >1400 (427) 1500 (457)
1280x960 <1300 (396) >1400 (427) 1500 (457)
1280x1024 <1300 (396) >1400 (427) 1500 (457)
1360x765 <1300 (396) >1400 (427) 1500 (457)
1365x768 <1300 (396) >1400 (427) 1500 (457)
1366x768 <1300 (396) >1400 (427) 1500 (457)
1440x960 <1300 (396) >1400 (427) 1500 (457)
1440x1050 <1300 (396) >1400 (427) 1500 (457)
1600x1200 <1300 (396) >1400 (427) 1500 (457)
1920x1200 <1000 (305) >1100 (335) 1200 (366)
2048x1080 <1000 (305) >1100 (335) 1200 (366)
720p <1300 (396) >1400 (427) 1500 (457)
1080i <1300 (396) >1400 (427) 1500 (457)
1080p <1300 (396) >1400 (427) 1500 (457)
NOTE: The maximum distance is defined as the distance from the first input signal
source to the last output signal display, regardless of the number and type of
devices between.
Input
Source
MTP Tx
Device
Display
MTP RL Rx
Device
Input
Source
MTP Tx
Device
MTP 1500RL
15HD RS Device
Display
Transmission distance with one device before the MTP 1500RL 15HD RS SEQ
Transmission distance with more than one device before the MTP 1500RL 15HD RS SEQ
VGA
cable
VGA
cable
TP
cable
1000 feet (305 m) maximum
(RS-232 data signals)
MTP 1500RL
15HD RS Device
VGA
cable
VGA
cable
TP
cable
TP
cable
1500 feet (457 m) maximum (video signals)
1500 feet (457 m) maximum (video signals)
1000 feet (305 m) maximum
(RS-232 data signals)
Figure 1. Maximum Transmission Distances
NOTE: The transmitter and receiver are designed for and perform best with Extron
Enhanced Skew-Free AV cable terminated in accordance with the TIA/EIA T568A
standard. CAT 5 cables are acceptable but less preferable. Using pre-terminated
and tested cables is also recommended. Cables terminated on-site should be
tested before use to ensure that they comply with Category 5 specifications.
MTP 1500RL 15HD RS SEQ • Introduction 2