User Guide User guide

4-7
MVX Plus 128 VGA A Matrix Switcher • Programmer’s Guide
PRELIMINARY
Command/Response Table for SIS
Commands
Symbol definitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D)
(use the pipe character,
|
, instead for Web browser commands)
= Space character
|
= Pipe (vertical bar) character
E
= Escape key (hex 1B)
(use W instead of Esc for Web browsers)
X!
= Input number 01 – 12
X@
= Input number (for tie)
00 – 12 (00 = untied)
X#
= Output number 01 – 08
X$
= Numeric dB value –18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)
X%
= Audio gain 0 – 24 (1 dB/step)
X^
= Audio attenuation 1 – 18 (1 dB/step)
X&
= Volume adjustment range 0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)
(default = 64 [0 dB])
See the table on page 4-10.
X*
= Room # (for room presets) 10 max. (each can have up to 10 presets (
X1@
s) assigned)
N
A Room is a subset of operator-selected outputs that relate to each other. The MVX Plus switchers support up to 10 rooms, each of which
can consist of from 1 to 16 outputs.
X(
= Mute, Lock mode, power supply 0 = off/mode 0/not OK
1 = on/mode 1/OK
2 = mode 2
X1)
= Group # (for I/O grouping) 1 through 4 groups (0 = no group)
X1!
= Global preset # 00 - 32 maximum (0 = current configuration)
X1@
= Room preset # 10 maximum (0 = current configuration for room)
N
A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,
it becomes the current configuration.
X1#
= RGB delay interval Delay in ½ second increments (10 maximum)
X1$
= Video/audio mute: 0 = no mutes
1 = video mute
2 = audio mute
3 = video and audio mute
X1%
= Sync frequency xxx.xx (frequency in Hz (V) or kHz (H))
X1^
= Connection status 0 = no input connected
1 = input connected
X1&
= Number of inputs 12
X1*
= Number of outputs 8
X1(
= Part number 68-788-01
X2)
= Firmware version number to second decimal place (x.xx)
X2!
= Verbose firmware version-description-upload date/time.
See the Query firmware version (verbose) command on page 4-16.
X2@
= Name 12 characters maximum for input names, output names, global preset
names, and room preset names
11 characters maximum for room names
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.
N
The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X2#
= Voltage Positive or negative voltage and magnitude
X2$
= Temperature Degrees Fahrenheit