Installation Guide RGB 400xi Series Installation Guide MK Box-Mounted Interface www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents About this Guide ....................................................................... 1 Installation Overview ............................................................. 1 Installation Instructions ........................................................ 2 Preparing the site and installing the MK box ......................... 2 Mounting the interface MK to the knockout box .................. 3 Specifications ............................................................................
Table of Contents, cont’d About this Guide This guide contains instructions for mounting the Extron RGB 460xi and 472xi MK interfaces in a standard, 2-gang MKstyle or KO-style knockout switch box that is used in Singapore, the United Kingdom, and Australia. The box used must have a depth of 47 mm at a minimum. This interface is a standard RGB 460xi or RGB 472xi interface, mounted to a faceplate, tailored to fit in the MK box.
Installation, cont’d Installation Instructions To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable. The MK box is not included with the interface; the installer is responsible for obtaining and installing the box. The MK box must have a minimum depth of 47 mm. 7.
Installation, cont’d 3. Mount the interface’s faceplate to the knockout box with M3, 30 mm machine screws (figure 3). Installation Cable RGB 460xi MK H. R NITO MO IN NO R NITO MO R NITO MO PU IFT SH X MA MIN/ T 0xi DIO AU MK B 46 RG M3, 30 mm Machine Screws Figure 3 — Mounting the interface to the MK box 4. Reconnect the power supply. Specifications This guide shows power requirements and physical specifications only.
Installation, cont’d Accessories High-resolution cables Audio connector Part number 3.
.0 .788 2X 1.088 1.313 1.788 2.415 2.623 2X 2.825 (DIM X B) 3.500 .770 .615 1.270 .474 .000 B B 3X Ø.125 THRU, wØ.220 X 90˚ FAR SIDE MARKED C INPUT C 1 INPUT 1 A 8 MONITOR INPUT 1 MONITOR FOLLOWS AUDIO 1 AUDIO 2 C SELECT 2 INPUT 2 SEE DETAIL D 0.340 THRU A NO MONITOR 2.600 1.690 1.490 0.100 X .210 RECT-THRU .000 .0 1.570 1.570 2.190 .539 1.945 2.020 B MONITOR H. SHIFT B AUDIO B INPUT MONITOR MIN/MAX C 2.220 MIN/MAX xi Series Installation Guide RGB 400xi .
10 The dashed line indicates the recommended cut-out area (2.68” H x 5.25” W) for the installation surface. The outside solid line (3.5” H x 5.83” W) represents the outside edge of the RGB 472xi wall plate. The inside solid line (3.38” H x 5.70” W) represents the outside edge of the RGB 460xi wall plate.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Installation Guide RGB 400xi Series Installation Guide MK Box-Mounted Interface www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.