Installation Guide RJ-45 to RJ-11 Conversion Kit Installation Instructions for HSA 400 Series and HSA 800 Series Enclosures www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents Chapter 1 • HSA 400, 402, 452 Installation ................. 1-1 Introduction ............................................................................. 1-2 Removing the HSA from the Table ............................... 1-2 Removing the Front Panel Connector ........................ 1-3 Replacing the Lower Enclosure Connector .............. 1-5 Replacing the Front Panel Connector and Reassembling the HSA ........................................................
Table of Contents, cont’d RJ-45 to RJ-11 Conversion Kit 1 Chapter One HSA 400, 402, 452 Installation Introduction Removing the HSA from the Table Removing the Front Panel Connector Replacing the Lower Enclosure Connector Replacing the Front Panel Connector and Reassembling the HSA Routing the AAP Cables ii RJ-45 to RJ-11 Conversion Kit • Table of Contents
HSA 400, 402, 452 Installation Introduction HSA 400 120-240 The Extron HSA 400, HSA 402, and HSA 452 ship with Category (CAT) 6 cables terminated with RJ-45 connectors between the front panel and lower enclosure bezel plug-ins. Some users prefer a telephone (RJ-11) connector. This conversion kit consists of a length of telephone cable terminated with RJ-11 connectors to replace one of the CAT 6/RJ-45 cables.
HSA 400, 402, 452 Installation, cont’d 125 - 50/ 60 Hz 5A HS A 40 2 H. SH IFT INP SEL UT ECT RG B 58 CO AU MP DIO UTE R 0xi SI AA 125 - 50/ 60 Hz 5A P HSA 402 Mounting Surface AAP Cables Figure 1-4 — Disconnecting the interior AC cable Remove two Allen screws ea. side. Clamshell 125 - IEC Power Cord 4 RJ-45 Connectors Flat Washer Full Thread Mounting Bolts HSA H.
HSA 400, 402, 452 Installation, cont’d Tie Wrap Tie Wrap Figure 1-6 — Releasing the bezel plug-in detent 2. Reach your hand through the access hole in the rear of the enclosure and snap the replacement RJ-11 connector onto the interior of the lower enclosure bezel plug-in. 3. Reconnect the interior AC power cable. 4. Use three tie wraps to bundle the power, CAT 6 and telephone cables (figure 1-7).
HSA 400, 402, 452 Installation, cont’d Icon Labels Page intentionally left blank Figure 1-8 — Changing the connector icon Routing the AAP Cables 1. Open the top panel to extend the AAP cables to their maximum pull. 2. Experiment with AAP cable positioning to ensure that the cables do not rub against the edges of the AAP cable hole and to ensure that the cable pull does not restrict the movement of the top panel. Figure 1-9 shows the cables routed to the side, which proved effective in tests at Extron.
HSA 400, 402, 452 Installation, cont’d RJ-45 to RJ-11 Conversion Kit Page intentionally left blank 2 Chapter Two HSA 800, 802 Installation Introduction Removing the HSA from the Table Replacing the Connectors Reassembling the HSA Routing the AAP Cables 1-10 RJ-45 to RJ-11 Conversion Kit • HSA 400, 402, 452 Installation
HSA 800, 802 Installation Introduction Removing the HSA from the Table The Extron HSA 800 and HSA 802 ship with Category (CAT) 6 cables terminated with RJ-45 connectors between the front panel(s) and lower enclosure bezel plug-ins. Some users prefer a telephone (RJ-11) connector. This conversion kit consists of a length of telephone cable terminated with RJ-11 connectors to replace one of the CAT 6/RJ-45 cables.
HSA 800, 802 Installation, cont’d Ensure that the edges of the connector panels do not scratch the finished surface of the top panel flange when removing the panels. HSA 802 125 INP SE UT LE CT CO MP UT - 50 /60 Hz 0.5 A AU DIO ER Remove two Screws ea. side. Remove 16 screws. Shroud HS 125 A8 00 - 50 /60 Hz 0.5A IN SE PUT LE CT CO MP AU UT ER DIO Remove panel from enclosure.
HSA 800, 802 Installation, cont’d 6. Route the conversion kit telephone cable in the same fashion as the removed CAT 6 cable. 7. Snap the replacement RJ-11 connectors on the conversion kit cable onto the interior of the front panel and lower frame bezel plug-ins. 6. Feed the cables connected to the AAPs in the HSA through the hole in the table and connect them to the devices that you disconnected them from in Removing the HSA from the Table, step 3 on page 2-3. 7.
HSA 800, 802 Installation, cont’d Secure AAP cables here View A Secure AAP cables here View B Figure 2-6 — HSA 802 AAP cable routing 3. 2-8 Use tie wraps to secure the AAP cables to the tie-down holes in the clamshell and enclosure.