User’s Manual SCP 150, SCP 150 AAP, and SCP 150 L Secondary Control Panels for the System 5 IP Switcher www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the SCP 150, SCP 150 AAP, and SCP 150 L . 1-2 Features ...................................................................................... 1-2 Chapter 2 • Installation and Operation .......................... 2-1 Installation Overview ......................................................... 2-2 Installing or Replacing Button Labels ......................... 2-2 Mounting Options ..............
Table of Contents, cont’d Accessories .............................................................................. A-4 Cables ......................................................................................... A-4 Panel Dimensions ................................................................. A-5 Templates ................................................................................. A-7 All trademarks mentioned in this manual are the properties of their respective owners. 68-717-01 Rev.
Introduction About the SCP 150, SCP 150 AAP, and SCP 150 L The Extron SCP 150, SCP 150 AAP, and SCP 150 L are hardwired remote control panels for the Extron System 5 IP switcher. All models replicate the switcher ’s volume, input switching, and system controls. The SCP 150 AAP also provides four spaces for the addition of optional architectural adapter plates (AAPs) or audio, relay, or IR control modules (ACMs, RCMs, IRCMs).
Installation and Operation Installation Overview 3. Separate the white backing from the clear button cap: insert the blade of the small screwdriver into the corner notch and gently twist the blade. 4. Save the translucent, white backing plate, but remove the text/label insert from the transparent button cap. 5. Select one of the premade button labels from the label sheets included with the SCP. Remove the label from its backing and peel the protective film from the front of the label, if applicable.
Installation and Operation, cont’d To mount the SCP 150 in areas of walls or furniture without studs, use an optional Extron 2-gang mounting bracket, part #70-086-01, -11, or -21. For the SCP 150 AAP, use an Extron 4-gang mounting bracket, part #70-086-03, -13, or -23. To mount the SCP 150 externally on a wall or desktop, use an optional Extron 2-gang SMB surface mount box, part #60-640-02. For the SCP 150 AAP, use an Extron 4-gang SMB, part #60-642-02.
Installation and Operation, cont’d Cabling the Rear Panel 3 Serial/host port — Use this 3-pole captive screw connector to connect to your PC’s RS-232 port. Extron Simple Instruction Set (SIS) commands can then be issued from the PC to monitor and obtain information from the SCP. This port is also used for uploading firmware to the SCP, if necessary. Refer to chapter 3, Remote Communication, for further details. Do not connect to this port if the SCP is being used with the System 5IP.
Installation and Operation, cont’d Pre-installation Testing/Troubleshooting Before mounting the SCP to the wall or furniture, test the system to make sure that the connections are correct and the panel is working correctly. Test the system by powering on the switcher, then pressing the input selection buttons on the SCP and watching the LEDs on the switcher to see if the system switches to the desired inputs.
Installation and Operation, cont’d Front Panel Features The controls on the SCP 150, SCP 150 AAP, and SCP 150 L replicate the System 5 IP’s volume, input switching, and system controls. All the button functions for the System 5 IP and the SCPs are configured via RS-232 or Ethernet control. See the System 5 IP user’s manual for instructions on configuring the buttons.
Installation and Operation, cont’d approximately 30 feet (9.14 meters) within 40 degrees on either side of the axis. See the following illustration.
Installation and Operation, cont’d SCP 150 PROJECTOR VOLUME IR Extron To reset, press these two buttons simultaneously while applying power to the SCP 150L.
Remote Communication Setting Up RS-232 Communication The RS-232 interface allows you to obtain information about the SCP and to activate certain SCP functions from a host computer or other device (such as a control system) attached to the rear panel RS-232 port (shown below). Gnd Rx Tx J1 Host-to-SCP communications SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence.
3-4 Examples: Q/q, I/i SCP 150 • Remote Communication Query firmware version—factory Query firmware version—updated Query part number Query firmware and build version Query model name/description Request control module and slave information. 1Q 2Q N/n +Q I/i 32I Query firmware version—factory and updated 0Q Q/q 31 51 32 51 4E 2B 51 31 49 33 32 49 30 51 51 If a command is not case-sensitive, this is indicated by showing the command letter in uppercase.
The syntax for setting a special function for an SCP 150 is X? * Y? * __ #, where X? is the value of the action to be performed, Y? is the value for the button or switch, and __ is the function number. To view a function’s setting, use __#, where __ is the function number. In the following table the values of the X? and Y? variables are different for each command/function. These values are given in the rightmost column.
3-8 SCP 150 • Remote Communication X? * Y? * 51# Lmp Y? SwRls * * X? X? X? 4 5 6 7 8 9 0 1 2 3 X? and Y? values is the LED state: = all LEDs off = green LED on = red LED on = green and red LEDs on (Button lights amber.
Remote Communication, cont’d Using the Switch/Function Button Table Switches are assigned to specific buttons on the SCP, any attached remote control module (IRCM/RCM/ACM), or the IR 402 remote. Each time a button is pressed or released, or a knob is turned on the SCP or a control module, the switch number associated with that button appears on your PC terminal emulator screen (HyperTerminal, etc.) as part of the host response.
Remote Communication, cont’d Updating Firmware If necessary, you can replace the SCP’s firmware without changing firmware chips. This procedure must be performed using a PC on which the Firmware Loader Software has been installed. The PC’s RS-232 port must be directly cabled to the SCP’s RS-232 port. CAUTION Do not attempt to upload firmware if a System 5 IP is connected to the SCP with any connections other than power. The RS-232 cable from the PC must be connected directly to the SCP. 4.
Remote Communication, cont’d The firmware update file must have a filename extension of .bin. If the file does not have that extension, it will not work properly. 11. Follow the instructions on the screen to upload the firmware. 12. When the firmware uploading is complete, the following dialog box appears: SCP 150 A Appendix A Specifications, Part Numbers, Accessories, and Dimensions Specifications Click OK to exit the Firmware Upload program.
Specifications, Parts, Accessories, Dimensions Control/remote — control pad Serial control port ........................ RS-232, via a 3.5 mm captive screw connector, 3 pole Baud rate and protocol ............... 9600 baud, 8 data bits, 1 stop bit, no parity Serial control pin configurations A = TX, B = RX, C = GND IR remote control ........................ IR 402 (optional) 30' maximum, 40 degrees off axis Program control .......................... Extron’s Simple Instruction Set (SIS™) General Power ....
Specifications, Parts, Accessories, Dimensions, cont’d Panel Dimensions Part number 4X Ø.160 THRU wØ.290 X 82° (CODED "E") 2X 2.980 5X Ø.125 THRU wØ.180 X 90° FAR SIDE 1.805 Accessories Ø.520 THRU SCP 150 5X .905 These items may be ordered separately: 1.320 Accessories R. 070 TOP EDGE ALL AROUND. 4.500 2-gang mounting bracket (gray, black, white, RAL9010) 70-086-01, -11, -21, -25 2X 3.858 3.505 3.390 3.
Specifications, Parts, Accessories, Dimensions, cont’d SCP 150 L Templates 4XØ .156 WØ .290 X 82° MARKED E The templates are not to scale and are provided for reference only. 6.500 2X 6.250 E E Top Panel 3.6" (9.15 cm) F Electrical Box 3XØ .120 WØ .220 X 82° MARKED F 4.875 2.8" (7.1 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT Location of SCP 150 F 2.755 2.250 SCP 150 1.625 F To install SCP 150 directly into furniture, cut along this line. TEMPLATE IS NOT FULL SIZE.
Specifications, Parts, Accessories, Dimensions, cont’d Cut-Out Template for Extron's SCP 150 AAP SCP 150 AAP TEMPLATE IS NOT FULL SIZE. To install SCP 150 directly into furniture, cut along this line. 7.2" (18.3 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT Top Panel 2.85" (7.2 cm) SURFACE CUT-OUT AREA FOR FURNITURE MOUNT 6.5" (16.5 cm) 3.6" (9.15 cm) Location of SCP 150 To install SCP 150 directly into furniture, cut along this line. 2.8" (7.1 cm) Electrical Box Top Panel 3.15" (8.