Owner manual

SCP 150 • Remote Communication
SCP 150 • Remote Communication
Remote Communication, cont’d
3-4 3-5
ASCII to HEX Conversion Table
ASCII to Hex conversion table
Symbol definitions
= CR/LF (carriage return/line feed) (hex 0D 0A)
= Soft carriage return (no line feed)
Esc
= Escape key
= Space
X1
= Firmware number
If a command is not case-sensitive, this is indicated by
showing the command letter in uppercase. followed by a
slash (/), then the same letter in lowercase.
Examples: Q/q, I/i
Command/response table for SIS commands
Command ASCII (Telnet) Hex Response Additional
(host to SCP) (host to SCP) (SCP to host) information
Query firmware version
Query Firmware version Q/q 51
X1
Shows current firmware
version.
X1
= current
firmware version number.
Query firmware version—factory and updated
0Q 30 51 x.xx, y.yyy
x.xx = factory firmware
version number format
y.yyy = updated firmware
version number format
Query firmware version—factory 1Q 31 51 x.xx
Query firmware version—updated 2Q 32 51 y.yy
Query part number N/n 4E 60-495-00
Query firmware and build version +Q 2B 51 x.xx.xxxx
Query model name/description I/i 31 49 SCP150
Request control module and slave 32I 33 32 49 P1##
P2## P1## = SCP address #
information. P2## = SCP address #