Operating Manual iCAM100
Operating Manual This page is intentionally left blank. Document Number 302803 (See Last Page for Revision Details) ©2006 Extronics Limited. This document is Copyright Extronics limited. Extronics reserve the right to change this manual and its contents without notice, the latest version applies.
Operating Manual Contents 1 2 Introduction.......................................................................................................... 4 Safety Information and Notes .............................................................................. 5 2.1 Storage of this Manual ................................................................................. 5 2.2 List of Notes ................................................................................................. 5 2.
Operating Manual 1 Introduction The iCAM100 is designed for use in Hazardous areas where a method of surveillance is required and space is at a premium. It is also ideal for monitoring plant or areas which are difficult to view due to its compact size. The iCAM100’s design means that it is suitable for use in both Zone 1 and Zone 2 environments. Please read the installation and operating instructions from cover to cover before installing and commissioning the iCAM100.
Operating Manual 2 Safety Information and Notes 2.1 Storage of this Manual Keep this user manual safe and in the vicinity of the device. All persons who have to work on or with the device should be advised on where the manual is stored. 2.2 List of Notes The notes supplied in this chapter provide information on the following. • Danger / Warning. o Possible hazard to life or health. • Caution o Possible damage to property. • Important o Possible damage to enclosure, device or associated equipment.
Operating Manual 2.3 Gland Special Conditions Important The Gland is only suitable in the temperature range of -60°C to +80°C Important When the gland is used for increased safety or dust protection, the entry thread shall be suitably sealed to maintain the ingress protection rating of the associated enclosure Important When used with unarmoured or braided cable, the gland is only suitable for fixed installations, the cable for which must be effectively clamped to prevent pulling and twisting 2.
Operating Manual 3 Installation & Setting To-Work The iCAM100 is very simple to install and can either be secure directly to suitable surface using the mounting holes on the module, or using the included wall bracket 3.1 Wiring Remove the iCAM100 lid by undoing the four screws (being careful not to loose the washers). Inside you will find a terminal block with four wires going to the camera unit, one twisted pair for power to the camera & one twisted pair for the video signal.
Operating Manual Caution Check wiring before switching on. 3.2 Mounting the Camera using the Wall Bracket Using the template supplied with each bracket, drill 3 x 7 mm Diameter holes each 45mm deep and clean out the holes. Insert one raw plug into each hole Pass a screw through each hole in the bracket and into the raw plug. Tighten all screws firmly.
Operating Manual 3.3 Pan and Tilt Adjustment To adjust the pan and tilt loosen the nut and bolt on the underside of the bracket, angle the camera to the required position and tighten the nut and bolt accordingly. 3.4 Mounting the Camera Directly The iCAM enclosure has four mounting holes located on its underside, which can be used to mount the camera directly or to the mounting plate for use with the wall bracket.
Operating Manual 4 Operation Once the iCAM100 is wired up all the unit requires is power and a suitable monitor to view the picture. There are no other adjustments on the camera itself apart from pointing the camera in the required direction using the pan and tilt. The iCAM100 does not require manual focusing, however it should be remembered that the optimal focal distance is dependent upon the lens used for the field of view.
Operating Manual 5 Intended Purpose Usage Important Before setting the units to work, read the technical documentation carefully. Important The latest version of the technical documentation or the corresponding technical supplements is valid in each case. The iCAM100 is built using modern components and is extremely reliable in operation; however it must only be used for its intended purpose.
Operating Manual 5.4 Safety Precautions Important For the installation, maintenance and cleaning of the units, it is absolutely necessary to observe the applicable regulations and provisions concerned with explosion protection (EN 50014, EN 6007914:2003) as well as the Accident Prevention Regulations. 5.5 Cleaning and Maintenance Intervals The cleaning intervals depend on the environment where the system is installed. 5.
Operating Manual 6 Technical Data Power Supply 19 to 32 V dc 1.2 W ,reverse polarity protected. 36 V over voltage protection Electrical Connection Screw terminals for cables up to 2.5mm Outputs PAL composite video Entries 1 x M20 for suitable Ex e glands Weight 650 g Mounting Universal wall mounting bracket with 360 degree horizontal pan and 70 degree vertical tilt Field of View Range 10 to 150 Degrees. See ordering information for further details Light Sensitivity 0.
Operating Manual 6.2 Power Supply Input Supply Specification Supply Voltage Range Absolute Voltage Limits Supply Power Consumption Units Min Max V 19 32 V 14 36 mW -- 1200 Units Min Max Vpp 1 Composite into 75R Vpp 2 Composite into 150R (Alternative output iCAM100-[#1]-D-[#3]) M 500 6.3 Video Signal Output Video Signal Specification Coaxial Composite Signal Differential Twisted Pair Typical distance (PSU/cable dependant) 6.
Operating Manual 6.5 CCTV Camera Module Electrical Details Video Sensor Specification Sensor type Units Min Max Video Signal (EU) PAL Light Sensitivity Lux 290 (H) x 320(V) 380 lines, 50 fields/sec 0.5Lux @ F2 5600ºK Signal to Noise Ratio Lens Field of View (FOV) Focus Iris db 48 degrees Select fixed board type lens from 9 to 90 Full Colour (PAL sensor) Fixed Automatic 6.
Operating Manual 7 Maintenance & Fault Finding 7.1 Maintenance Note: The iCAM 100 does not require any active maintenance, if however the iCAM 100 enclosure is opened, it is necessary to ensure that the lid is replaced correctly and securely, otherwise the iCAM may not comply with the ATEX regulations. It is recommended that the iCAM 100 is regularly inspected for deterioration caused from wear and tear, accidental damage, rust, corrosion of chemicals etc.
Operating Manual 8 Type Codes Compact Colour CCTV Camera Specify Field of View [#1] Angle of View Focal Length iCAM100-[#1]-X-P-[#4] Recognition Distance 30M 16M 12 8M 6M 4M 3.5M Best Picture 19° 16.0mm 12 28° 12.0mm 6 40° 8.0mm 4 53° 6.0mm 2.3 80° 4.0mm 2 92° 3.6mm 1.8 130° 2.97mm 1.
Operating Manual 9 EC Declaration 18
Operating Manual 10 ATEX Certificates Junction box 19
Operating Manual 20
Operating Manual 21
Operating Manual 22
Operating Manual 23
Operating Manual 24
Operating Manual 25
Operating Manual 26
Operating Manual Camera Module 27
Operating Manual 28
Operating Manual Cable Gland 29
Operating Manual 30
Operating Manual 31
Operating Manual 32
Operating Manual 33
Operating Manual 11 Manual Revision Revision 11 12 13 14 15 16 Description Changed manual to new format Changed technical information Updated ATEX Certificate on Camera Module Amended ordering information Removed NTSC Option Changed Cable Gland Type Date 23/10/07 13/03/08 02/05/08 21/05/08 09/07/09 04/05/10 By James Eastwood James Eastwood James Eastwood James Eastwood James Eastwood James Eastwood Nick Saunders 34 Digitally signed by Nick Saunders DN: CN = Nick Saunders, C = US Reason: I have reviewe