2.3 Gland Special Conditions
Important The Gland is only suitable in the temperature range of -60°C to +80°C
Important When the gland is used for increased safety or dust protection, the entry
thread shall be suitably sealed to maintain the ingress protection rating
of the associated enclosure
Important When used with unarmoured or braided cable, the gland is only suitable
for fixed installations, the cable for which must be effectively clamped to
prevent pulling and twisting
2.4 Camera Module Special Conditions
Important The free end of the permanently connected cable shall be protected in
accordance with EN50014:1997 clause 14.1.
Important In accordance with EN 50018:2000 clause 13.4.2 the rear end of bushing
shall be protected by fitting it into a suitably certified enclosure. In
addition, the bushing must not be subject to torque during installation.
Improtant The product shall not be connected to portable equipment.
Important The product that is fitted with a window has only been subjected to
reduced risk impact tests in accordance with EN 50014:1997 clause
23.4.3.1; therefore it shall not be mounted in an area where there is a
high risk of impact.
Important The product shall be earthed in accordance with EN 50014:1997 clause
15 when fitted to a suitably certified enclosure