User guide

Operating Manual
5
Warning! For Class 1 Division 1 applications the rated ambient temperature range
of the equipment is from -20
o
C to 55
o
C/50
o
C dependent on the cells used
(see Table 1).
Warning! Any connection to the iCAM501U USB port must NOT be made in a
hazardous area.
Warning! If any damage to the iCAM501U is found which may invalidate the
required safety minimum IP rating (IP54 for group I applications), (IP20
for group II and class 1 division 1 applications), the iCAM501U shall be
removed from the hazardous area.
Important Any repairs or replacement of parts MUST be performed by the
manufacturer or its nominated sub contractor or agent.
Important The iCAM501U contains no user serviceable parts. The main part of the
enclosure must not be opened under any circumstances.
Table 1 iCAM501U cell usage table
Application
Duracell
Plus
MN1500
Duracell
Procell
MN1500
Duracell
Procell
PC1500
Energizer
E91
LR6XWA
ATEX
/IECEx
GROUP II
OK, T4 at
60
o
C
OK, T4 at
60
o
C
OK, T3 at
60
o
C
OK, T3 at
60
o
C
OK, T3 at
60
o
C
ATEX
/IECEx
GROUP I
OK, T4 at
60
o
C
OK, T4 at
60
o
C
CANNOT
BE USED
CANNOT
BE USED
CANNOT
BE USED
CLASS
1
DIVISION 1
OK, T4 at
55
o
C
OK, T4 at
55
o
C
OK, T3C at
50
o
C
OK, T3C at
50
o
C
CANNOT
BE USED