Instructions / Assembly
Page 23 of 74 
3.4.  INSTALL GROUND TRANSITION RAMP 
3.4.1.  The PRGT (RAMP GROUND TRANSITION) consists of two sections that need to be 
installed into the ramp and connected together. 
The PRGT (RAMP GROUND TRANSITION) is only designed to transition from the 
lowest ramp in the run to the ground. Do NOT USE in any other location. 
3.4.2.  Lift the lowest end of the ramp/ramp run and bring the upper section PRGT into the 
ramp end tread until the “hook” is engaged FIG. 3.10), then rotate into place (FIG. 
3.11) and set back on the ground. 
FIG. 3.10 
FIG. 3.11 
3.4.3.  Slide the lower section ground transition ramp into upper section (FIG. 3.12). 
3.4.4.  Install #8-32 x 1/2” hex washer head thread cutting screws into the screw slots on 
both sides where the sections connect (FIG. 3.13). 
  The hex washer head screws will keep the sections from sliding with respect to 
each other but the sections can still be separated until they are installed in the 
ramp and resting on the ground. 
3.4.5.  Holes and fasteners are included for anchoring into wood or concrete. Other 
methods may be used when anchoring into other surfaces. 
3.4.6.  If connecting the lowest end of the ramp to a PLP (LANDING PAD) use a PRLT (RAMP 
LOWER TRANSITION) instead of a RAMP GROUND TRANSITION. Please see ‘OPTIONAL 
EQUIPMENT’ section for instructions. 
FIG. 3.12 
FIG. 3.13 