Instructions / Assembly

PVC INTERLOCKING LINER PANEL
Technical & Install Guide
Silicone Sealant
After the installation is complete, a manufacturer approved silicone sealant
may be used around xtures, seal corners, and repair small holes. A one-
part, neutral cure, white sealant is recommended. Always check the
product label to ensure PVC compatibility. Unapproved sealants may
chemically attack the panel.
Note: Painting PVC panels is not recommended. If painting is necessary, check
with the manufacturer to ensure the paint is compatible with PVC. Never use
paint thinner to remove paint from the panel. Paint thinner is highly incompatible
with PVC.
Fasteners
Below is a recommended fastener hardware guide for typical EZ Liner
PVC interlocking applications.
Wood - #8 x 1 1/4” Square Truss Head
Metal - #8 x 1 1/4” Square Pan Head
Concrete - #11 x 1 1/4” Tapcon
Note: Do not use nails or staples. Only use fasteners recommended for your
specic application. Length of screw is determined by specic installation.
Plastic Spacers
In a wet environment installation, plastic spacers may be used to create
the necessary gap o󰀨 the oor (about 1 or 25mm). Spacers may also
be used when mounting a heavy object to the wall like an electrical box,
preventing the PVC panel from being crushed if the mounting screws
are overtightened.
You can special order any of the install components. If you have any questions concerning the
install components required or need to order for your project, please contact Polymershapes at
(800) 421-0102 or send an email to retail@polymershapes.com.
EZ LINER™ PVC Panel Installation
Cutting
EZ LinerPVC interlocking panels can be cut with common power or manual tools depending on the type
of cut. We recommend using a circular saw with a fine tooth blade. For cutouts such as electrical boxes,
a jigsaw is recommended.
retail@polymershapes.com | (800) 421-0102
7
J-Trim
Multi-H
Inside
Corner
Cove
90-Trim
EZ Liner™ PVC Trim System