DOMESTIC TANKLESS GAS WATER HEATER USER’S MANUAL EZ Supreme Read the installation instructions before installing the appliance. Read the user’s instructions before powering on the appliance.
NOTICE: For your safety and the safety of others, this heater cannot be connected to an existing natural draft exhaust. Only the sealed-joint concentric intake/exhaust components made specifically for this heater can be used.
Important things to remember during installation and initial operation 1. Direct Vent pipes – Make sure both intake-exhaust pieces (the 94 degree bend and the 31inch long straight piece) are connected AND that each connection is sealed with heat sealant tape. 2. Heated Room – Be sure that the unit is being installed inside a heated room. 3. Plumbers Putty/Tape – Be careful not to over apply plumber’s putty/tape to the inlet and outlet water fitting.
PLEASE COMPLETELY READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your water heater properly. A little preventive care on your part can save you time and money over the life of your water heater. You’ll find many answers to common problems in the Troubleshooting Guide. If you review the chart of Troubleshooting Tips first, you may not need to call for service.
DANGER! PROPERLY INSTALL AND VENT THIS WATER HEATER… Failure to properly install and properly vent the water heater to the outdoors as outlined in the Venting Section of the Installation Instructions in this manual can result in unsafe operation of the water heater. To avoid the risk of fire, explosion or asphyxiation from carbon monoxide, never operate this water heater unless it is properly vented and has an adequate air supply for proper operation.
INSTALLATION: Contact your local gas dealer or utility company specialist for a qualified engineer to evaluate your plans and always use a qualified technician to install the gas water heater.
NOTICE: FOR YOUR SAFETY, PLEASE READ THIS MANUAL CAREFULLY AND FOLLOW ALL DIRECTIONS. 1) Follow all local codes, or in the absence of local codes, follow the most recent edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA or the CAN/CSA B149.1 Natural Gas and Propane Installation Code in Canada. 2) Properly ground the unit in accordance with all local codes or in the absence of local codes, with the National Electrical Codes, ANSI/NFPA 70 in the USA or CSA standard C22.
Model identification information EZ Official EZ tankless water heater brand NG Natural Gas (model for this gas type) LP Liquid petroleum gas “propane” (model for this gas type)
DANGER: When this heater is in use, there is obviously a combustion process which generates heat to make hot water. The combustion of almost all combustible materials and flammable gases of any kind typically consumes a large amount of oxygen and in turn this combustion process produces many different by-products in the smoke (exhaust) which include Carbon Monoxide. Regardless of how clean the combustion process is, there are always exhaust gasses that are emitted at some level.
NOTICE: This heater is not designed to be mounted in areas outdoors or unheated structures if temperatures can drop below freezing. When the temperature of the room in which this heater is mounted drops below freezing the residual water must be drained from this unit. WARNING: FOR YOUR SAFETY, READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot.
FEATURES: This tankless water heater uses the Direct Vent Exhaust System. This is absolutely the safest and most economical ventilation method in use among tankless water heaters. This method uses a dual-chamber intake/exhaust pipe and a forced air system. This model is suitable for showering, using the sink, a clothes washing machine or even your dishwasher.
ADVANCED DIGITAL CONSTANT TEMPERATURE TECHNOLOGY: ”Set it and forget it” technology. Set your EZ SUPREME tankless water heater to the desired temperature and the computer controlled system will keep the flowing water at a constant temperature, no matter the change in water flow. (NOTE: Within the limits of the design and specified GPM capacity) TOUCH CONTROL PANEL SETTINGS: Design includes easy to operate LCD display of temperature settings, which can be adjusted using the simple “+” and “-“ buttons.
SPECIFICATIONS Name Gas-fired tankless water heater Model EZ SUPREME NG or LPG Type Gas type Natural Gas or LPG Category I2H LPG (0.46) (11"wc)/NG (0.29) (8"wc) Rated gas pressure O Nominal heat input (temperature rise 25 C) Qn kW Gallons per minute rating G/min Application water pressure psi Energy Factor 50 (164,000 btu) 6.4 GPM @ 45 degree rise (F) 20 ~ 100 PSI .84 Min.
TEMPERATURE CONVERSION CHART FOR USA USERS
TROUBLE SHOOTING AND COMMON QUESTIONS Q - I don't have any hot water when I open the tap! A - Make sure there is gas, water and electricity to the Water Heater (the power is turned on and the gas is turned on) Q - When I was using the hot water, the water got cold! A - If you adjusted the flow from the tap to lessen it, you may have gone below the minimum flow required. The Water Heater requires a minimum flow rate to operate (see specification page for flow rate of your unit).
MORE TROUBLE SHOOTING HINTS
NOTE: All specifications are subject to change without notice.