Use and Care Manual
Table Of Contents
1. DIAL POSITIONING (PRE-FIRST IGNITION)
a. WaterFlowDial-ewatertemperaturedialshouldberstsettothe“low”setting.
b. Winter/SummerDial-ewinter/summerknobshouldberstsettothe“summer”setting.
c. FlameDial-eamedialshouldberstsettothe“low”setting.
2. GAS SUPPLY
Gas supply to the EZ 101 unit should only be propane (lpg) regulated to a pressure setting of 11”WC. e EZ 202
Natural Gas requires 8” WC. Lower or higher pressures beyond this value will deliver inconsistent ignition and
operation and are not recommended.
3. WATER SOURCE
Inletwatersourceshouldbeatleast1gpmlteredwaterataminimumpressureof8PSI.Wateroworwater
pressure values less than these recommended may result in unit failing to ignite.
4. ADJUSTMENTS FOLLOWING FIRST IGNITION
Note: ese adjustments should be made with the unit running and heating water.
a. Toincreasewaterow,slowlyturnwatertemperaturedialcounterclockwise.If,whileincreasing
waterow,theEZ101amesout,slowlyreturndialclockwiseuntilunitreignites.
Stop! At point of reignition you have reached the maximum ow rate as provided by your
chosen water inlet source.
b. Toincreasewatertemperature,slowlyturnthe“ame”dialclockwise.Ifyoureachthemaximum
amelevelandthewaterisstillnotwarmenough,returnthe“ame”dialtothelowsettingand
attempt “step c”. When desired water temperature is set, do not reset the dials until a new water
source is provided.
c. Turn the winter/summer dial counter clockwise to the next setting. e dial will lock into place
when turned to each setting. With the dial at the new setting return to step “b” and continue to
nd desired temperature setting.
4.0 INITIAL SETUP AND OPERATION
EZ TANKLESS 101 OPERATION + INSTALLATION MANUAL PAGE 08..
Note: ese steps should be followed for every new location or water source