Use and Care Manual
Table Of Contents
1. CHECK THE GAS HOSE AND REGULATOR FOR ANY DEFECTS
Propane regulators, especially single stage regulators, defect at a high rate predominantly due to age. Most single
stage regulators will eventually allow a higher pressure than the required 11”WC by the EZ 101. When this hap-
pens the unit will not ignite. is is the most common fault that causes ingnition failure.
2. CHECK THE EXHAUST VENT FOR BLOCKAGE REGULARLY
Debris, animals, or insects may enter the exhaust vent at anytime. Be sure to regularly check the exhaust vent
for any blockage. A blockage of the exhaust vent will cause inconsistent water temperatures as well as potential
damage to internal components.
3. CLEAN INLET WATER FILTER SCREEN REGULARLY
Located just inside of the water inlet tting on the bottom of the EZ 101 is a lter screen. is screen is used to
keep sediment and small debris from entering the heat exchanger. Be sure to regularly check this screen for any
debris that it may have caught. Remove the screen from the inlet using a small pick or screwdriver, blow away or
rinse away any debris that may have accumulated and reinstall the lter screen into the water inlet before next
use.
4. FLUSH UNIT ONCE A YEAR
With the heating of water through a heat exchanger comes the build up of minerals over time throughout the
waterheaterpartsandcomponents.Itisrecommendedtoushyourtanklesswaterheaterwithdistilledwhite
vinegar at least once per year when used on a regular basis, to ensure continued use and to avoid parts damage.
5. ALWAYS KEEP COVER OF UNIT CLEAN
e cover of your water heater will become hot during use. It is not recommended to place any stickers, magnets,
or other decorative material on the cover of the EZ 101. Be sure to wipe away any dirt or debris that may be on
the cover before each use.
5.0 RECOMMENDED EZ101 MAINTENANCE
EZ TANKLESS 101 OPERATION + INSTALLATION MANUAL PAGE 10..