Instructions / Assembly

1. DIAL POSITIONING (PRE-FIRST IGNITION)
a. WaterFlowLever-Thewaterflow levershouldbefirstsettothe“low”setting.
b. Burner Dial -TheburnerknobshouldbefirstsettotheI (single burner)setting.
c. FlameLever-Theflamelevershouldbefirstsettothe“low”setting.
2. GAS SUPPLY
Gas supply to the EZ 202 LPG unit should only be pressure setting of 11”WC. The EZ 202 Natural Gas requires
8” WC. Lower or higher pressures beyond this value will deliver inconsistent ignition and operation and are not
recommended.
3. WATER SOURCE
Inletwatersourceshouldbeatleast1gpmfilteredwaterataminimumpressureof8PSI.Waterfloworwater
pressure values less than these recommended may result in unit failing to ignite.
4. ADJUSTMENTS FOLLOWING FIRST IGNITION
Note: These adjustments should be made with the unit running and heating water.
a. Toincreasewaterflow,slowlypushwaterflow leverto the left.If,whileincreasing waterflow,the
EZ202flamesout,slowlyreturnlever to the rightuntilunitreignites.
Stop! At point of reignition you have reached the maximum flow rate as provided by your
chosen water inlet source.
b. Toincreasewatertemperature,slowlypushthe“flame”lever to the left.Ifyoureachthe
maximum flamelevelandthewaterisstillnotwarmenough,returnthe“flame”levertothelow
settingand attempt “step c”. When desired water temperature is set, do not reset the dials until a
new water source is provided.
c. Start with the burner selection knob on I. If your desired temperature is not reached with burner
selection knob on I and flame set to high, turn the flame back to low and set burner selection
knob to II. Repeat steps B&C until the desired temperature is reached. Our recommended
temperature is between 41-49C (105-120F)
PAGE 08..EZ TANKLESS 202 OPERATION + INSTALLATION MANUAL
4.0 INITIAL SETUP AND OPERATION
Note: ese steps should be followed for every new location or water source