Instructions / Assembly

4.1 CONTROL DIALS INFORMATION
1. BURNER SELECTION I, II, III
The burner selection knob will provide the largest fluctuation in delivered water temperature. This
dial regulates the internal burners within the system. I - 1 Burner, II - 2 Burners, III - 3 Burners
2. Gas Flow Lever
The gas flow lever controls the height of the flame to each burner. This lever is used to fine tune
temperature after selecting the correct burner setting for your water flow.
3. WATER FLOW LEVER
The water flow lever provides the greatest level of control over ignition level. This lever controls water flow
throughthesystem.TheEZ202usesawaterpressureactivatedvalvetocontroltheelectronicignitionandgas
flowthroughtotheburners.Iftheusersetsthewaterflowdialatthe“high”setting(highestamountofwater
flow)buthasawatersourcewithlessthan4gpm,therewillnotbealargeenoughbuildofpressureinthe
water/gasdiaphragmtoengagethepressurevalve.Thisiswhyitisalwaysrecommendedtosetthewaterflow
lever to“low” during initial setup/first ignition.
EZ TANKLESS 202 OPERATION + INSTALLATION MANUAL
PAGE 09.
1
2