Instructions / Assembly

1. CHECK THE GAS HOSE AND REGULATOR FOR ANY DEFECTS
Propane regulators, especially single stage regulators, defect at a high rate predominantly due to age. Most single
stage regulators will eventually allow a higher pressure than the required 11”WC by the EZ 202 LPG. When this
happens the unit will not ignite. This is the most common fault that causes ignition failure.
2. CHECK THE EXHAUST VENT FOR BLOCKAGE REGULARLY
Debris, animals, or insects may enter the exhaust vent at anytime. Be sure to regularly check the exhaust vent for
any blockage. A blockage of the exhaust vent will cause inconsistent water temperatures as well as potential
damage to internal components.
3. CLEAN INLET WATER FILTER SCREEN REGULARL
Y
Located just inside of the water inlet fitting on the bottom of the EZ 202 is a filter screen. This screen is used to
keep sediment and small debris from entering the heat exchanger. Be sure to regularly check this screen for any
debris that it may have caught. Remove the screen from the inlet using a small pick or screwdriver, blow away or
rinse away any debris that may have accumulated and reinstall the filter screen into the water inlet before next
use.
4. FLUSH UNIT ONCE A YEAR
With the heating of water through a heat exchanger comes the build up of minerals over time throughout the
waterheaterpartsandcomponents.Itisrecommendedtoflushyourtanklesswaterheaterwithdistilledwhite
vinegar at least once per year when used on a regular basis, to ensure continued use and to avoid parts damage.
5. ALWAYS KEEP COVER OF UNIT CLEAN
The cover of your water heater will become hot during use. It is not recommended to place any stickers,
magnets, or other decorative material on the cover of the EZ 202. Be sure to wipe away any dirt or debris that
may be on the cover before each use.
5.0 RECOMMENDED EZ 202 MAINTANENCE
EZ TANKLESS 202 OPERATION + INSTALLATION MANUAL
PAGE 10..