RF Field Strength Meter RF-194
1 Introduction This meter is designed for measuring and monitoring electromagnetic field value of the Radio –Frequency The meter is calibrated precisely on the frequency value 2.45 GHZ 2 Application This meter is applied to measuring electromagnetic fields of Radio –Frequency of normal or 2.
4 Identifying Parts 1. Sensor position. 2. LCD 3. Zero button 4. Power on/off 5. maximum hold and minimum hold select button 6. Frequency Team select button 7. Data hole button 8. Tripod mounting screw 9.
5 Measurement Procedures Press button to power on. Press button test frequency to select 2.45 GHZ or normal (50MHz to 3.5 GHz). Position the top (refer to Figure 1) of the meter to measure the electromagnetic waves. Try to change the measurement angle or position for obtaining the highest reading value (please refer to Figure 2 to 6). Due to the environmental magnetic field factors, this magnetic field meter could display a reading value that is lower than 0.002 mW/cm^2 prior to measuring.
Figure 1 indicates the correct measurement direction of the RF electromagnetic field strength measurement. Figure 2, 3, 4, 5 and 6 indicate the incorrect measurement direction of the RF electromagnetic field strength measurement. AUTO POWER OFF function 1. In order to save the battery power the meter will be off after 30 minutes of non-use. 2. To disable this function please turn off the power then hold MAX/MIN key ,press power key. 3.
Specifications Display: 3-3/4 digits LCD, maximum reading 3999. Resolution: 0.001mW/cm^2. Frequency response: 50MHz to 3.5 GHz. Sensor: Single Axis. Accuracy: ±2 dB at 2.45 GHz ± 50MHz. Over load: LCD display “OL”. Sample rate: 2.5 times per second. Battery: 9V NEDA 1604, IEC 6F22 or JIS 006P. Battery life: Approximate 100 hours. Operating temperature & humidity: 5℃to 40℃,below 80% RH. Storage temperature & humidity: -10℃ to 60℃, below 70%. Weight: About 170g.
Battery replacement WARNING If the symbol “ ” appears on the LCD, please replace the battery immediately Turn off the instrument. Remove the battery cover. Replace the battery. Install the battery cover. 8 Safety Precaution For cleaning the instrument use a soft dry cloth. Never use a wet cloth, solvents or water, etc.. Operation Altitude: Up to 2000M. Operating Environment: Indoors use. This instrument has been designed for being used in an environment of pollution degree 2.
9 End of life Caution: this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal