User's Manual
71
www.lairdtech.com
Laird Technologies
BTM510/511
Bluetooth
®
Multimedia Module
HFG”VGS<n>”
Speaker gain setting message was received from HF (“+VGS:<n>”) with n = gain [0..15].
HFG”VGM<n>”
Microphone gain setting message was received from HF (“+VGM:<n>”) with n = gain [0..15].
HFG”AU1”
Audio connection (SCO) has been established (= “audio on”).
HFG”AU0”
Audio connection (SCO) has been released (= “audio off”).
HFG”C”
A call has been established and is ongoing.
HFG”T”
A call has been terminated.
HFG”R”
Incoming call was rejected by HF.
HFG”OP?”
Request for network operator string (“AT+COPS?”) received from HF. AG is expected to
reply with “+COPS:0,0,<operator_string>” on SLC. Use AT+HFGO”<operator_string>”.
HFG”Dnnn”
Request from HF to place an outgoing call to phone number provided by HF with
<nnn> = number string. The AG is expected to conrm the outgoing call with the
command AT+HFGC1.
HFG”D>nnn”
Request from HF to place an outgoing call using memory dialling with <nnn> = memory
location. The AG is expected to either conrm the outgoing call with the command
AT+HFGC1 or to respond with AT+HFGE if the memory location is invalid.
HFG”L”
Request from HF to place an outgoing call using the last number dialled. The AG is expected
to either conrm the outgoing call with the command AT+HFGC1 or to respond with
AT+HFGE if the last number dialled is not available.
HFG”Mn”
Request from HF to generate DTMF code <n> towards the telephony network.
HFG”CLIP1”
Request to activate caller line identication notication in the AG.
HFG”CCWA1”
Request to activate call waiting notication in the AG.
HFG”CMEE1”
Request to activate extended AG error result codes in the form +CME ERROR: <err>.
NO CARRIER 111F
Service level connection to local HFG-instance has been released. Please note section 6, page 85.
AT COMMAND SET
REFERENCE