8.3 Reflow Parameters
Laird Technologies surface mount modules are designed to be easily manufactured, including
reflow soldering to a PCB. Ultimately it is the responsibility of the customer to choose the
appropriate solder paste and to ensure oven temperatures during reflow meet the requirements
of the solder paste. Laird Technologies’ surface mount modules conform to J-STD-020D1
standards for reflow temperatures.
Important: During reflow, modules should not be above 260° and not for more than 30 seconds.
Figure 8-2: Recommended Reflow Temperature
Temperatures should not exceed the minimums or maximums presented in Table 9.
Table 9: Recommended Maximum and minimum temperatures
Specification
Value
Unit
Temperature Inc./Dec. Rate (max) 1~3 °C / Sec
Temperature Decrease rate (goal) 2-4 °C / Sec
Soak Temp Increase rate (goal) .5 - 1 °C / Sec
Flux Soak Period (Min) 70 Sec
Flux Soak Period (Max) 120 Sec
Flux Soak Temp (Min) 150 °C
Flux Soak Temp (max) 190 °C
Time Above Liquidous (max) 70 Sec
Time Above Liquidous (min) 50 Sec
Time In Target Reflow Range (goal) 30 Sec
Time At Absolute Peak (max) 5 Sec
Liquidous Temperature (SAC305) 218 °C
Lower Target Reflow Temperature 240 °C
24