Datasheet

dbl_pimf.pdfIssue24.03.2017 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
Data cable Li2YCY PiMF
conductor material: bare copper
conductor construction: fine stranded, class 5
insulation: polyethylene
stranding unit: pair
screen over stranding unit: foil
stranding: pairs in layers
screen over strand: Cu-braid, tinned
screen coverage: 80 %
sheathing material: PVC
colour of outer sheath: grey
flame retardant: VDE 0482-332-1-2/IEC 60332-1-2
max. operating temperature,
fixed:
-15 - +70 °C
temperature, moved/during
installation:
-5 - +70 °C
bending radius, fixed
installation:
12 x DA
insulation resistance: 5000 MOhmxkm
specific inductivity: 0,4 mH/km
operating capacity: 75 nF/km
nominal voltage U: 250 V
test voltage: 1 kV
core identification: colours acc. DIN 47100
Application: Data cable with low operating capacity, pairs individually screened and common copper screen. Suitable
for connection of control devices in environments with high level of electrical interferences. For fixed installation inside
of buildings.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
Table: Technical characteristics Li2YCY PiMF
p/n part name D
A.
[mm]
G
.
[kg/km]
Cu
.
[kg/km]
031749 Li2YCY PiMF 02X2X0,22 GR 7,7 75 33
034575 Li2YCY PiMF 03X2X0,22 GR 8,1 86 35
034581 Li2YCY PiMF 10X2X0,34 GR 14,3 230 150
031796 Li2YCY PiMF 02X2X0,5 GR 9,7 96 47
031703 Li2YCY PiMF 03X2X0,5 GR 10,4 116 64
031797 Li2YCY PiMF 04X2X0,5 GR 11,4 141 109
p/n part name D
A.
[mm]
G
.
[kg/km]
Cu
.
[kg/km]
034587 Li2YCY PiMF 02X2X0,75 GR 10,4 117 61
034589 Li2YCY PiMF 04X2X0,75 GR 12,4 222 141
032365 Li2YCY PiMF 02X2X1 GR 11,8 130 72
031778 Li2YCY PiMF 04X2X1 GR 14 360 187

Summary of content (2 pages)