Data Sheet
dbl_iysty.pdfIssue23.11.2018 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
Telecommunication cable J-
Y(St)Y ... Lg acc. to VDE 0815
CPR-performance: Eca
Conductor material: copper, bare
Conductor class: class 1 = solid
Insulation: PVC TI1
Stranding unit: pair
Stranding: layers
Screen over strand: foil
Drain wire: yes
Sheathing material: PVC YM1
Colour outer sheath: grey RAL 7032
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Permitted outer cable
temperature, fixed:
-30 - +70 °C
Permitted outer cable
temperature, in motion/
during installation:
-5 - +50 °C
Bending radius, fixed
installation:
7,5 x DA
Bending radius, single bend: 2,5 x DA
Insulation resistance: 100 MOhmxkm
Coupling K1: 300 pF
Maximum operating capacity: 100 nF/km
peak operating voltage: 300 V
Core identification: colours acc. to VDE 0815
Application: Preferably for telecommunication installations inside buildings in dry and humid rooms, but also for
permanent installation at external walls if protected from sunlight. These cables are not approved for high-voltage
applications.
Additional information: Stranding: cores twisted into pairs (2-pairs cable stranded as star-quad), pairs stranded in
layersCore identification: two-pair cable: red, black, white, yellow. More than two-pairs are in continuous sequence:
white-blue, white-yellow, white-green, white-brown, white-black. In the 1-st pair of each layer tehere is one red core red
in place of the white one.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
Table: Technical characteristics I-Y(St)Y ... Lg
p/n part name D
A.
[mm]
G
.
[kg/km]
Cu
.
[kg/km]
100001 J-Y(St)Y 01X2X0,6 GR 5 30 7
100003 J-Y(St)Y 02X2X0,6 GR 5,5 35 13
p/n part name D
A.
[mm]
G
.
[kg/km]
Cu
.
[kg/km]
100005 J-Y(St)Y 03X2X0,6 GR 6,3 50 18
100007 J-Y(St)Y 04X2X0,6 GR 6,8 55 24