Instructions / Assembly

17
RIDGE & GABLE DETAILS
GABLE TRIM
SEALANT IS USED BETWEEN
RIDGE & GABLE AND
UNDER GABLE LAP
FASTENER
RIDGE
RIDGE DETAIL
ROOF STRUCTURE
FASTENER 9" C/C MAX
#14 x 1 1/2" LONG
TOP & BOTTOM OF
SEALANT TAPE
29 GA. AGRI
PANEL
RR-1 or AR-3
RIDGE CAP
OUTSIDE CLOSURE
VENTED RIDGE
Note: RX10 Versavent can be used instead of Profilevent (shown)
#14 x 1 1/2" LONG FASTENER
9" C/C MAX
29 GA. AGRI PANEL
ROOF STRUCTURE
RIDGE CAP
A
R-3
PROFILE VENT
Notes:
1. Roofing underlayment not shown.
2. Plywood should be held back or cut back 1½” from each side of the ridge.
3. Attach the panels checking the 1” minimum overhang at the eave.
4. Mark edge of ridge cap on both sides of the peak. Unroll profile vent and press into place about 1” upslope of mark.
5. The gable flashing must be installed prior to the ridge installation.
6. Fasten the ridge cap using #14 x 1½” MP screws on each panel rib 1” back from the edge of the profile vent
HIP DETAIL
ROOF STRUCTURE
TOP & BOTTOM OF
SEALANT TAPE
29 GA. AGRI
PANEL
RR-1 or AR-3
RIDGE CAP
STRIP
SEALER
#14 x 1 1/2" LONG
FASTENER 9" C/C MAX
HIP ROOF—PLAN VIEW
HIP CAP
29 GA. AGRI PANEL
Note:
1. Hip flashing attachment same as ridge (see detail above).