(N.m) (‘‘)
Min. Max.
(N.m) (mm)
E.506-135S
0,1 1/2
6,8135
80
E.506-200S
0,1 1/2
10200
80
E.506-340S
0,1 1/2
17340
80
Dear User,
Thank you for purchasing this digital torque-angle adaptor.
This manual will help you to use the many features of your new digital
torque-angle adaptor. Before operating the torque adaptor, please read
this manual completely, and keep it nearby for future reference.
MAIN FEATURES
Digital torque-angle value readout
+/-2° ( rotating 90° at speed of 30°/sec) for angle accuracy
+/- 3% or +/- 4% for torque accuracy
CW and CCW operation
Buzzer and LED indicator for the 9 pre-settable target torques or angles
Five Units Selectable (N.m, ft-lb, in.lb, kg.cm, degree)
50 data memory for recall and joint torque-angle auditing
Auto Sleep after about 2 minutes idle
Both AAA and rechargeable batteries are compatible
NAMES AND FUNCTIONS OF PARTS A
1. LED Indicator 7. Memory Number
2. Buzzer 8. Buttons
3. LCD Display 9. Communication Port
4. Torque/Angle Value 10. Extension bar
5. Units 11. Battery cover
6. Peak/Track Mode
E.506-135S - E.506-200S - E.506-340S
Torque Accuracy *1 CN / CW :±3% CCW :±4%
Angle Accuracy *2 +/- 2° ( rotating 90° at speed of 30°/sec)
Measured Angle Range
999.0°
Data memory size 50
PC Connectivity *3 No
Pre-setting No 9 sets
Bright LED 12 LED / 2 Red+10 Green
Torque Operation Mode Peak Hold / Track
Unit selection N.m, ft-lb, in-lb, kg.cm, degree
Button 5
Battery AAA x 2
Battery Life *4 (Continuous operation) 24 hrs.
Battery Life *4 (Standby) 1 Year
Operating Temperature
-10°C 60°C
Storage Temperature
-20°C 70°C
Humidity Up to 90% non-condensing
Drop Test 1 m
Vibration Test *5 10 G
Life time *6 10000 cycle
Environmental test *7 Pass
Electromagnetic compatibility test *8 Pass
SPECIFICATIONS
A
B
1
2
3
7
8
4
5
6
10
9
11
M
E.506-200S
903613
E.506-340S
903621
E.506-135S
903605
Press
Instruction manual
N.m
M
T
Current target torque
Torque zero reset
M
Current target angle
Torque zero reset
Note: *1: The accuracy of the readout is guaranteed from 20% to 100% of
maximum range +/- 1 increment. For maintaining accuracy, calibrate the
adaptor at regular intervals (1 year recommended).
*2: The angle accuracy is guaranteed at ±2° when rotating adaptor
to 90° at speed of 30°/sec.
*3:
Use a special designed cable (accessory) to upload record data to PC.
*4:
Use two AAA batteries (Tested condition: Toshiba carbon-zinc battery)
*5: Horizontal and vertical test.
*6: One cycle means turning the torque adaptor from 0 N.m to
maximum torque and back to 0 N.m.
*7: Environmental test: a. Dry heat e. Impact (shock)
b. Cold f. Vibration
c. Damp heat g. Drop
d. Change of temperature
*8: Electromagnetic compatibility test:
a. Electrostatic discharge immunity (ESD) b. Radiated susceptibility
c. Radiated emission
BEFORE USING THE ADAPTOR
BATTERY INSTALLATION B
Loosen the screw of the battery cover.
Insert two AAA batteries matching the -/+ polarities of the battery to
the battery compartment.
Put on the battery cap and rotate it tightly according to the following fi gures.
POWER ON AND AUTO ZERO RESET
• Let the adaptor be sat without touching it
• Gentlely press
to power on.
• Auto zero-reset will be processed fi rst.
• The adaptor will be started in torque or angle mode.Which mode will be
started depends on in which mode the adaptor is powered-off last time.
• In torque mode, fi rst is torque zero-reset and then a target torque screen
will show.
• In angle mode, it fi rst do several seconds of angle- zero-reset and then a
target angle screen will show.(Very important issue: See attention)
• If it takes too long in angle reset, press
will perform reset again.
Press
Press
ATTENTION:
1. If
is appeared, refer to “ERROR MESSAGE”.
2. IMPORTANT!
During angle reset, keep the adaptor still and never shake, vibrate or even
touching the adaptor.
If the adaptor is moving again and again, the zero reset will not stop.
Finally,
will be shown.( Refer to “ERROR MESSAGE”)
AUTO POWER OFF
The adaptor will auto power off after about 2 minutes idle for power saving.
CAUTIONS:
During communication period (
appears), the auto power-
off function is disabled.
• Press for zero reset.
• Usually press
to zero reset
the digital torque-angle adaptor before using the adaptor.
It will guarantee a better accuracy.
• In angle mode, please keep the adaptor steady without any disturbance
and press to do zero-reset.
• In torque mode, if an external force is applied to the torque adaptor
during zero-reset period, an initial torque offset error will occur.
HARDWARE RESET
To do haraware reset, remove battery and re-install it.
If the adaptor does not function normally or
appeares,
please go through the reset process to reset the adaptor.
ERROR MESSAGE
LOW VOLTAGE INDICATOR
If the battery voltage is too low, the adaptor will display a battery
symbol and then turn off. Replace batteries.
When
shows during power-on process, it means this
adaptor has ever been applied more than 110% of torque of the
spec.The accuracy of torque may be lost.
In angle mode, if the adaptor does not reset successfully for a period
of time,
will be shown. Press to do zero-reset
again. Notice that during resetting process, never vibrate or shake
the adaptor. Keep it rest.
shows that the adaptor does not work functionally,
please do hardware reset. Refer to “HARDWARE RESET”.
In angle mode, iff the adaptor rotates too fast,
will be
shown.Do press
to zero reset the adaptor.
OPERATION
Low battery indicator
FAST GETTED START
Press
to power on. No appling forces on adaptor.
Target torque or angle will be shown.
Press
to select the torque unit or “ ° ” (angle mode)
and then press
to set target value
.
Or press
to select the pre-set target values
.
Press
to reset adaptor.(suggested)
.
Start to rotate adaptor.
Watch out the warning LED, sounds and LCD to stop rotation.
T-mode torque operation
In T-mode, LCD displays the current torque value.
After release force, the LCD value will return to O.
P-mode torque operation
In P-mode, LCD displays the maximum torque value.
After release force, the LCD shows the catched maximum value. (fl ashing)
Now press
to record maximum torque value, or press to clear it.
Angle operation
In angle mode, LCD displays the angle rotated after the reaching over 5% of
the rated maximum torque.
Now press
to record angle value, or press to clear it.
1- INSTALL THE ADAPTOR AND POWER ON
Press to power on the adaptor.
2- NO APPLING FORCES ON ADADAPTOR