FAGOR NC-200 PB NC FOR PRESS BRAKES INSTALLATION MANUAL Manual version: 0111
INDEX Declaration of conformity ................................................................................... 4 Safety conditions ............................................................................................... 5 Warranty terms ................................................................................................... 7 Material returning terms ......................................................................................
4. 4.1. 4.2 Operation with the RS-232-C serial line ....................................... 49 Saving and restoring data ...................................................................49 Parameter transmitting format .............................................................49 5 5.1 5.1.1 5.2 5.2.1 5.2.2 5.2.3 SETUP ............................................................................................ 50 Test mode ..............................................................................
DECLARATION OF CONFORMITY Manufacturer: Fagor Automation, S. Coop. Barrio de San Andrés s/n, C.P. 20500, Mondragón -Guipúzcoa (ESPAÑA) We hereby declare, under our responsibility that the product: NC Fagor NC-200 PB meets the following directives: SAFETY: EN 60204-1 Machine safety. Electrical equipment of the machines. ELECTROMAGNETIC COMPATIBILITY: EN 50081-2Emission EN 55011 EN 55011 Radiated. Class A, Group 1. Conducted. Class A, Group 1. EN 50082-2 Immunity EN 61000-4-2 Electrostatic Discharges.
SAFETY CONDITIONS Read the following safety measures in order to prevent damage to personnel, to this product and to those products connected to it. Fagor Automation shall not be held responsible for any physical or material damage derived from the violation of these basic safety regulations. Do not open this unit Only personnel authorized by Fagor Automation may open this unit. Do not handle the connectors with the unit connected to AC power. Before handling the connectors (mains, feedback, etc.
Working environment This unit is ready to be used in Industrial Environments complying with the directives and regulations effective in the European Community Install the unit in the right place It is recommended, whenever possible, to instal the DRO so its power switch of the back panel is at a distance between 0.7 m (27.5 inches) and 1.7 m (5.6 ft) off the floor and away from direct sunlight, hot air, coolants, chemical products, blows as well as from relays, or high electromagnetic fields (about 0.
WARRANTY TERMS WARRANTY All products manufactured or marketed by Fagor Automation has a warranty period of 12 months from the day they are shipped out of our warehouses. The mentioned warranty covers repair material and labor costs, at FAGOR facilities, incurred in the repair of the products. Within the warranty period, Fagor will repair or replace the products verified as being defective.
MATERIAL RETURNING TERMS When returning the DRO, pack it in its original package and with its original packaging material. If not available, pack it as follows: 1.- Get a cardboard box whose three inside dimensions are at least 15 cm (6 inches) larger than those of the unit. The cardboard being used to make the box must have a resistance of 170 Kg (375 lb.). 2.
DESCRIPTION OF THE DIFFERENT MODELS (THEY MAY BE SELECTED WITH PAR64) A. Controlling only the final position of the bend. The foot switches and the hydraulic circuit are not controlled by this NC. The intermediate positions of the ram are detected by electrical microswitches. A1. Same as model "A" with footswitch treatment and outputs for governing the hidraulic valves for the 4 EXECUTION modes. The rapid approach feed is not managed. Especially indicated for conventional down-stroke machines. B.
DIAGRAM OF A TYPICAL PRESS BRAKE + Y - X Page: 10 - Installation Manual - NC-200 PB +
1. UNIT DESCRIPTION This unit is especially designed to be used on punch presses. It allows displaying the position of the X and Y axes, controlling them as well as the raising device (H), editing and executing part programs etc. The axes may also be moved manually from the dro keyboard or externally with footswitches. 1.1 FRONT PANEL (SEE OPERATION MANUAL) 1.2 REAR PANEL 1 2 3 Dimensions of the Built-in model (in mm): On the back of the unit, the following items may be found: 1.- Power switch. 2.
X2.- SUB-D type 37 pin female connector to connect the digital inputs and outputs as well as the analog outputs. X3.- SUB-D HD type 15-pin female connector for X axis feedback device. X4.- SUB-D HD type 15-pin female connector for Y axis feedback device. X5.- SUB-D HD type 15-pin female connector for 2nd axis feedback device. auxiliary Y' axis (only on model "B"). X7.- SUB-D type 9 pin male connector for the RS-232-C serial line connection.
2. CONNECTIONS AND CHARACTERISTICS The connection for the RS-232 serial line (optional X1 connector) is not described in this manual; but in a supplement for it. 2.1 CONNECTION OF THE FEEDBACK SYSTEMS The feedback systems (scales or encoders) are connected via SUB-D HD type 15-pin female connectors: X3 and X4. Characteristics of feedback inputs: X3, X4 and X5: +5V input consumption: 250 mA - Admits square-wave signal (TTL).
2.2 INPUT/OUTPUT CHARACTERISTICS (X2) A 37-pin female connector is used. Signal characteristics of connector "X2": The supply voltage is at +24V (±25%), thus the threshold between a "0" and a "1" will be about +6V.
2.3 INPUT/OUTPUT CONNECTION (X2).
PIN 11, 12, 30, 31 FUNCTION Limit switches. Hardware DESCRIPTION In MANUAL mode, they limit the movement in the corresponding direction. In EXECUTION mode, they abort the program.
2.3.2 OUTPUT DESCRIPTION If any of the outputs is going to be connected to some highly inductive device, a "1N4000" type diode must be installed in antiparallel. It is not required on auxiliary relays of less than 20 mA. The drives are enabled with auxiliary relays (section 5.2). PIN 5, 6, 7, 24, 25, 26 18, 37 FUNCTION Axis enable FAST/SLOW DIRECTION PAR46 Analog voltage outputs. PAR 64, PAR65 DESCRIPTION Enabling drives or frequency inverters for open loop control.
19 PRESSURE SENSOR M 29 28 9 13 32 15 23 MANUAL 27 H AXIS 10 IN POSITION X ENABLE 5 X SPEED 6 X DIRECTION 7 ANALOG X 18 GNDA ace RETRACT RAM BUZZER NEXT BLOCK FEED/RETRACT X AXIS I rf nte EMERGENCY Page: 18 - Installation Manual - NC-200 PB LIMIT X- LIMIT X+ 11 12 X3 X2 X4 Encoder 16 EXTERNAL KEY SIMULATION 36 35 8 ß x1 14 LIMIT Y- 34 Y Dis.
MANUAL H AXIS FEED RAM PRESSURE SENSOR M 27 10 29 28 9 13 32 15 23 X ENABLE 5 X SPEED 6 X DIRECTION 7 ANALOG X 18 GNDA ce RETRACT RAM BUZZER NEXT BLOCK FEED/RETRACT X AXIS In fa ter EMERGENCY LIMIT X- 35 8 11 12 LIMIT X+ MOTOR CONTROL "BEND" FOOTSWITCH "RETRACT" FOOTSWITCH X3 X2 X4 Encoder RUN 1 RUN 2 36 "BCD" JOG SET 16 ß x1 14 LIMIT Y- 34 Y Dis.
19 RETRACT RAM RAM FAST MANUAL H AXIS RAM SLOW MANUAL STATION FAST FEED M 27 10 29 28 9 13 32 15 23 X ENABLE 5 X SPEED 6 X DIRECTION 7 ANALOG X 18 GNDA ace TABLE TRAVEL LIMIT FEED X AXIS I rf nte EMERGENCY LIMIT X- LIMIT X+ 35 8 11 12 X3 X2 X5 X4 Encoder RUN 1 RUN 2 36 "BCD" JOG SET 16 ß x1 14 LIMIT Y- 34 Y Dis.
19 MANUAL H AXIS BUZZER M 27 10 9 29 28 13 32 15 23 X ENABLE 5 X SPEED 6 X DIRECTION 7 ANALOG X 18 GNDA ce FREE FREE FREE FREE MANUAL STATION FAST FEED In fa ter EMERGENCY LIMIT X- 35 8 11 12 LIMIT X+ MOTOR CONTROL "BEND" FOOTSWITCH "RETRACT" FOOTSWITCH X3 X2 X4 Encoder RUN 1 RUN 2 36 "BCD" JOG SET 16 ß x1 14 LIMIT Y- 34 Y Dis.
2.3.4 BLOCK CHANGE SYNCHRONISM. MODELS A, A1 Description of the diagrams according to positions a, b and c. There are three ways to synchronize when going from one block to the next at the end of a bend. If a pressure gage (transducer) is installed, P64.6 = 1, the editor offers the possibility to program the work pressure on the header page N0. 1. With the transducer connected to input I18 (P64.
Par64 (6) = 1 Par64 (7) = 0 1- Pressure analog input I18 Analog Input (A) IN_POS O29 BEND RETURN O28 CHANGE I13 BLOCK a b 2- Pressure analog output c Par64 (6) = 1 Par64 (7) = 1 I18 Analog Output I15 Pressure level (A) IN_POS O29 BEND RETURN O28 CHANGE I13 BLOCK a 3- Pressure gage input b c Par64 (6) = 0 I15 Pressure level (A) IN_POS BEND O29 RETURN O28 BLOCK I13 CHANGE Block change a b1 b2 b1 b3 NC-200 PB - Installation Manual - Page: 23
2.3.5 BLOCK CHANGE SYNCHRONISM. MODEL B Description of the diagram according to positions 1 through 6: 1. With X and Y axis already in position, the FAST approach is activated from the MANUAL control station IE15 or only SLOW from the "BEND" footswitch (I8). 2. In the change position, Y= PAR33 or programmable, the SLOW speed is activated with the "BEND" footswitch. 3. When pinching the sheet metal, Y = thickness, it resets O29 to wait for the return of the X axis. 4.
- Position Y' - Auxiliary scale PAR33 Programmed Y coordinate Y' = e FAST/SLOW change Programmable top dead point By default: PAR28 D programmable By default: P29 SLOW O29 ·I8 ·I8 ·I8 I8 Retract X FAST 09 ·I15 I35 in EXEC. RUN1, RUN2 RAM DOWN O28 MANUAL-SET ·I35 JOG BEND footswitch 1 2 3 4 5 6 X, Y axes IN POSITION.
2.4 MACHINE REFERENCE (HOME) SEARCH In this mode, the initial values are preset in a fixed reference position. If PAR14.4 = 1 on any axis, home search is mandatory on that axis every time the machine is turned on. This unit starts in mode. To quit this mode without homing, press and key in the access/exit code: 719200 If PAR14.4 = 0, home search is only required on machine setup.
2.4.2 Y AXIS REFERENCE (HOME) SEARCH. MODELS A AND A1 a- If the machine has travel limit switches, the home search procedure is the same as the one described for the X axis; but it is only enabled if I13 = 1, ram at top dead position. b- If the machine does NOT have travel limit switches (which is very common on down stroke models), set PAR14 bit 1 = 1 to indicate that the reference position is floating.
2.4.3 Y AXIS HOME SEARCH. MODEL "B" Usually, this axis has home switches on UP-STROKE models. · Position the table or the ram at the far-end position activating the limit switch I13. · Press . The · Select the · Press led turns on. axis. It displays the word "START". to reach the home position. · Actuate on the "BEND" footswitch until the punch or the die (on up-stroke models) goes to its final position.
2.4.4 Y AXIS HOME SEARCH. MODEL "C" An up-stroke or down-stroke model "C" has a linear encoder and controls the actual (real) position of the ram using foot switches. It usually has travel limit switches. If PAR00 bit 6 = 0, has been set for a linear encoder with a regular reference mark (without distance-coded reference marks), the homing procedure is the same as described in section 2.4.2 (a) If PAR00 bit 6 = 1 has been set for a linear encoder with distance-coded reference marks.