Owner’s Manual Scale Store Electronic Table Top Scale Series DPB Series 50701 © 2010 by Fairbanks Scales, Inc.
Amendment Record SCALE STORE DPB SERIES OWNER’S MANUAL Document 50701 Manufactured by Fairbanks Scales, Inc. 821 Locust Kansas City, Missouri 64106 Created 06/97 Created document Revision 1 06/97 Document release Revision 2 06/10 Revised manual 06/10 3 50701 Rev.
Disclaimer Every effort has been made to provide complete and accurate information in this manual. However, although this manual may include a specifically identified warranty notice for the product, Fairbanks Scales makes no representations or warranties with respect to the contents of this manual, and reserves the right to make changes to this manual without notice when and as improvements are made.
Table of Contents TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SECTION 1: GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 POWER . . . . . . . . . . .
Section 1: General Information INTRODUCTION The CHC Series Electronic Bench Scale is designed to be a simple-to-operate, general purpose scale. An audible signal is given each time a key is pressed to insure error-free operation. Models are available in 12, 25, and 60 pound capacities. Each model has a bright, easy-to-read LED display. All weights are convertible between pounds and kilograms. The scale is intended for use in non-commercial applications and is not legal-for-trade.
Section 2: Features 1-1 POWER SUPPLY 1. The power switch is located on the bottom of the scale on the right side. 2. The power supply is AC 110V or AC 200V ±10%, 50/60 HZ 1-2 KEYPAD DESCRIPTION THE SCALE STORE TARE SET ON OFF CHANGE SET WEIGHT MODE TARE ZERO DPB 12W W E I G H T THE SCALE STORE ON OFF CH SET MODE TARE SET TARE ZERO DPB 65 50701-1 06/10 7 50701 Rev.
1-3 KEY BUTTON FUNCTION ON OFF Press the ON/OFF key to power on or power off the scale. Turn the scale OFF to conserve battery power when weighing is complete. CHANGE The CHANGE or CH key is to set minimum graduations. These can be set at three different levels. Press this key to change the minimum graduation. SET CAL MODE TARE ZERO + 06/10 The SET key is for the Checkweighing function. 1. Place the desired weight to be used on the platform. 2.
Section 2: Calibration 2-1 NOTES Before beginning the calibration procedure, be sure to power off the scale and empty the weighing platform. Use calibration standard of more than one-sixth (1/6) of the scale’s maximum capacity. During calibration, use standard weights that are not over the scale’s maximum capacity. For example, if calibrating a 25-pound capacity scale, use a standard 5-pound weight to calibrate it. 2-2 KEYPAD FUNCTION CHART SET The SET key is used to confirm a setting.
6. Press the ZERO key again to display the numbers 123. ZERO (+) 123 P6 7. P6 will display on screen, followed by 999999. 99999 30.00 8. The scale capacity will appear after 20 seconds. 9. Press the ZERO key to change the first digit to zero. 30.00 00.00 ZERO (+) 10. Press the CHANGE key to change the flashing digit (going from left to right). 11. Press the ZERO key to change the flashing digit from 0 to 5. 12. Place the standard 50-lb.
This page left blank intentionally. 06/10 11 50701 Rev.
SCALE STORE DPB SERIES Manufactured by Fairbanks Scales, Inc. 821 Locust St. Kansas City, MO 64106 www.fairbanks.