Owner manual
Section 5: Commissioning
05/11 56 51209 Revision 2
5.7.4 Configuring Inputs
An action both for signal change from 0 to 1 (on) and from 1 to 0 (off) can be determined for each of
the three inputs. The action may be dependent on another condition which must be met.
Setup/Digital I/O parameter
Output 1 marker bit 1 X64=1
Output 2 marker bit 2 X65=1
Output 3 marker bit 3 X66=1
Input 1 on
set tare
X113=1
Condition no condition -----
Input 1 off -no action-
Input 2 on -no action-
Input 2 off -no action-
Input 3 on -no action-
Input 3 off -no action-
1. Determining an action
Determine the action for the rising edge of input 1 under [Input 1 on] from the following list (here:
When the input signal changes from 0 to 1, a tare command is generated).
Accordingly, an action for the falling edge can be determined.
Selection list for actions of the inputs [Input 1/2/3 on/off]
Function SPM bit
-no action- ----- No function
set marker 1 X64=1 Set marker 1
set marker 2 X65=1 Set marker 2
set marker 3 X66=1 Set marker 3
select net X72=1 Select net
set zero X112=1 Set zero
set tare X113=1 Set tare
reset tare X114=1 Reset tare
set test X115=1 Activate the analog test
reset test X116=1 Finish the analog test
reset PWF X117=1 Reset power fail
set fixtare X118=1 Set fixtare (use the value in address D31 as a tare value)
get fixtare X119=1 Save gross value as fixtare in address D31
set print X120=1 Activate a print order
clr marker 1 X64=0 Clear marker 1
clr marker 2 X65=0 Clear marker 2
clr marker 3 X66=0 Clear marker 3
select gross X72=0 Save the gross weight in address D11