Owner manual

Section 5: Commissioning
05/11 60 51209 Revision 2
5.8 Analog Output
Determine the analog output under -[Analog output parameter].
Setup
Serial ports parameter
Date & Time
Fieldbus parameter
Network parameter
Calibration
Limit parameter
Digital I/O parameter
Analog output parameter
Press and
to select [Analog output parameter]
Setup/Analog output parameter
Analog mode
no output
Analog range 0 ... 20 mA
Output on error 0 mA
Output if < 0 0 mA
Output if > Max 20 mA
Weight at 0/4 mA 0 kg
Weight at 20 mA 3000 kg
[Analog mode] [no output] The analog output is not used
[Gross
D08]
Output of the gross weight
[Net D09]
Output of the net weight
[Select
D11]
Output of the value on the display
[Transparent
D30]
Output of the value in D30
[Analog range] [0...20 mA] Output of 0... 20 mA
[4...20 mA] Output of 4... 20 mA
[Output on error] [0 mA] Set the output to 0 mA
[4 mA] Set the output to 4 mA
[20 mA] Set the output to 20 mA
[hold] The last output value is held
[Output if < 0] [0 mA] Set the output to 0 mA
[4 mA] Set the output to 4 mA
[20 mA] Set the output to 20 mA
[linear] The output drops below 4 mA up to the limitation
(at 4 .. 20 mA)
[Output if > Max] [0 mA] Set the output to 0 mA
[4 mA] Set the output to 4 mA
[20 mA] Set the output to 20 mA
[linear] The output exceeds 20 mA up to the limitation
[Weight at 0/4 mA]
Weight value for 0/4 mA output
[Weight at 20 mA] Weight value for 20 mA output
Press
to return to the previous menu [Configuration].