30
INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
Fixed Wiring
Disconnect from the mains supply.
For connection to xed wiring, i.e. exible conduit, Remove
the electrical terminal cover on the back panel (Fig. 9.15).
Remove the M4 screw securing the reducer plates to the
conduit box (Fig. 9.16). Fit the conduit box to the range using
the two M5 screw ttings located at the top of the box and
the M4 screw (Fig. 9.17).
The conduit box cover is reversible. Fit the reducer plates, if
required (Fig. 9.18). Feed the cable through the conduit box
and secure in place with the cable clamp.
Connect the mains cable to the correct terminals for your
electrical supply type (Fig. 9.19). Check that the links are
correctly tted and that the terminal screws are tight.
Fit the cover to the conduit box.
Repositioning the range following
connection
If you need to move the range once it has been connected
then you need to unplug it and, having gripped under the
fascia panel and lifted the front of the range slightly
(Fig. 9.6), you need to check behind the range to make sure
that the electricity cable is not caught.
As you progress, make sure that the electricity cable always
has sucient slack to allow the range to move.
When you replace the range, again check behind to make
sure that the electricity cable is not caught or trapped.
Conduit box
M4 screw
M5 screws
Reducer plates
M4 screw
Reducer plates
Reversible conduit box cover
ArtNo.132-0002 - 3 phase 240/415Vac 50Hz
3-phase 400 V
AC
50 Hz
Fig. 9.15
Fig. 9.16
Fig. 9.17
Fig. 9.18
Fig. 9.19