User's Manual
Table Of Contents
- U111316 - cover [Aus]
- U111316-01 PROFESSIONAL+ FXP 90 DUAL FUEL [AUS]
- 1. Before You Start...
- 2. Overview
- 3. 6 Button clock
- 4. Cooking tips
- 5. Cooking Table
- 6. Cleaning your cooker
- 7. Troubleshooting
- 8. Service and Spares
- 9. Installation
- Safety Requirements and Regulations
- Provision of Ventilation
- Location of Cooker
- Conversion
- Positioning the Cooker
- Moving the Cooker
- Removing the Oven Door
- Lowering the Two Rear Rollers
- Completing the Move
- Levelling
- Fitting the Stability Bracket and Chain
- Fitting a Stability Bracket
- Fitting the Restraining Chain
- Gas Connection
- Pressure Testing
- Electrical Connection
- Fixed Wiring
- Final Checks
- Final Fitting
- Customer Care
- Fitting the drawer
- Removing the drawer
- 10. Conversion to propane gas
- 11. Servicing
- 12. Circuit Diagram
- 13. Technical Data
- Blank Page
- Blank Page
- Blank Page
- Blank Page
45
13. Technical Data
This cooker is designed for use on Natural gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity and on rear of the appliance.
COUNTRY OF DESTINATION: Australia.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural Gas
1 kPa
230 V 50 Hz
Propane 2.54 kPa
See the appliance badge for test pressures.
Dimensions
Model Professional+ FX 90 Dual Fuel
Overall height minimum 905 mm maximum 930
mm
Overall width 900 mm
Overall depth 608
mm excluding handles, 645 mm including handles
Minimum height above the hotplate 650 mm
Hotplate Ratings
BSI Evo 1 Type Burners Australia
Burner Type
Bypass
Screw*
Natural Gas 1.0 kPa Propane 2.54 kPa
Input
Injector
Input
Injector
Marking Size Ø Marking Size Ø
Wok 75 15.2 MJ/h-
1
198 1.93 mm 15.0 MJ/h-
1
111 1.07 mm
Rapide / Large 41 12.3 MJ/h-
1
165 1.65 mm 12.0 MJ/h-
1
89 0.96 mm
Semi Rapide / Medium 33 6.2 MJ/h-
1
115 1.15 mm 6.2 MJ/h-
1
67 0.68 mm
Auxillary / Small 25 3.7 MJ/h-
1
92 0.92 mm 3.3 MJ/h-
1
45 0.50 mm
* The valves in this cooker are tted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural gas. For LPG conversion the
bypass screws must be screwed all the way down.
Hotplate energy saving tips Oven energy saving tips
Use cookware with a at base. Cook meals together, if possible.
Use the correct size cookware. Keep the pre-heating time short.
Use cookware with a lid. Do not lengthen cooking time.
Minimise the amount of liquid or fat. Do not open the oven door during the cooking period.
When liquid starts boiling, reduce the setting. Do not forget to turn the appliance o at the end of cooking.
Consumption is based on G30.