User Manual

PART 1: HOOD INSTALLATION GUIDE - WALL HUNG
W
ALL HUNG CANOPY
Models include LATINA F5LT90S1, TREVISO F5TV90S1, ROMA F5RM90B1, MODENA F5ME12S1 and
TRENTO F5TN12S1
STEP 1:
Measure the height of the hood from the base to the top of the mounting hooks.
NOTE:
The height of the underside of the hood body must be a minimum of 600 mm above an electric cooktop & 650 mm above a
gas cook top and a maximum height of 1200 mm. If the instructions of the hob specify a greater distance than the minimum
detailed, this shall be the minimum height for installation. Building codes that stipulate a minimum dimension may vary from
state to state, please check with your local council prior to installation.
MODENA F5ME12S1 & TRENTO F5TN12S1 models only - The height of the underside of the hood body must be a
minimum of 1200 mm above a BBQ.
STEP 2:
Using a spirit level mark a vertical centre line on the wall where the hood hooks need to be positioned. It is best to centre the
hood unit to the cook top below.
STEP 3:
Mark a horizontal line on the wall for the mounting bracket position. Centre and mark the two (2) fixing points to the left and
right of the centre line.
STEP 4:
Drill and plug holes with suitable sized wall plugs. Fix the wall bracket with two (2) suitable screws into the wall at the positions
marked in step 3 to allow the body of the hood to be hung on the wall.
STEP 5:
Hang the body of the hood on the wall using the bracket attached in step 4.
Adjust the alignment of the hood using the fixing screws located in each bracket. The upper screw (B) adjusts the distance
from the wall , the lower one (C) the vertical scrolling.
Identify and mark several screw holes located inside the hood. Remove the hood from the wall and drill and plug holes with
suitable sized wall plugs.
STEP 6:
Replace the hood back on the wall and secure the hood by fixing the additional screws inside the hood housing.
WARNING
DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, PR KITCHEN & WASHROOM
SYSTEMS PTY LTD RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.
FOR BUILDING PURPOSES THE UNIT SHOULD BE PROVIDED TO THE CABINET MAKER /
BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.