CONGRATULATIONS Congratulations and thank you for choosing a Falmec rangehood. To avoid the risks that are always present when you use an electrical appliance it is important that the rangehood is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards. We recommend that you keep this instruction booklet for future reference and pass it on to any future owners.
PRODUCT DESCRIPTION & CARTON CONTENTS CARTON 1 - HOOD UNIT You will be supplied with one of the three hood unit options detailed below. OPTION 1 - INTEGRATED HOOD - ON BOARD HOOD Models include: SIENA F3SN60S1, F3SN90S1 and F3SND90S1 Included in the carton: 1. Main hood housing including control module and lighting 2. Baffle filters 3. Grease trap 4. Fixing screws 5.
PRODUCT DESCRIPTION & CARTON CONTENTS CARTON 2 - FAN MOTOR UNIT You will be supplied with one of the two fan motor options detailed. OPTION 1 - IN ROOF SOLUTION (FIG.4a) Models include: IR-765 and IR-1140 Unit designed to be located in a roof space and then ducted to an external vent. Included in the carton: 1. In Roof Motor Unit 2. Mounting Bracket 3. Fixing Screws 4. Duct Clamps x4 5. 200 mm Flexi Duct (5 Meters Length) 6. White Stainless Steel Eave Vent (FIG.4a) OPTION 2 - EXTERNAL ROOD SOLUTION (FIG.
SAFETY INSTRUCTIONS AND WARNINGS Installation operations are to be carried out by skilled and qualified installers in accordance with the instructions in this booklet and in compliance with the regulations in force. DO NOT use the hood if the power supply cable or other components are damaged: disconnect the hood from the electrical power supply and contact the Dealer or an authorised Servicing Dealer for repairs. Do not modify the electrical, mechanical or functional structure of the equipment.
OPERATION OPERATING YOUR CONTROL PANEL WITH THE 6 SENSOR TOUCH CONTROL Turning the extraction function ON or OFF: • In standby mode, press button 2 to turn on operating mode, then press buttons 3 through to 5 to change the speed. • The hood has three speed options and a boost speed plus the off function. • To turn hood off, press button 2 repeatedly until hood returns to standby mode.
USIN THE RADIO CONTROL 2) - PAIRING THE RADIO CONTROL WITH THE HOOD USING THE ELECTRONIC PUSHBUTTON PANEL WARNINGS!: The radio control is optional. Follow the entire procedure described below if purchased. Place the hood away from sources of electromagnetic waves (e.g. microwave ovens), which could interfere with the radio control and with the hood electronics. The maximum operating distance is 5 metres, that may vary according to the presence of electromagnetic interferences.
GREASE DRIP TRAY MAINTENANCE Before cleaning or carrying out maintenance operations, disconnect the equipment by removing the plug or switching off the main switch. Do not use detergents containing abrasive, acidic or corrosive substances or abrasive cloths. Regular maintenance guarantees proper operation and performance over time. Special attention is to be paid to the metal anti-grease filters: frequent cleaning of the filters and their supports ensures that no flammable grease is accumulated.
FUMES DISCHARGE (SIENA F3SN60S1, F3SN90S1 and F3SND90S1 ONLY) In this version the fumes and vapours are discharged outside through the exhaust pipe. To this end, the hood outlet fitting must be connected via a pipe, to an external output. The outlet pipe must have: • A diameter not less than that of the hood fitting. • A slight slope downwards (drop) in the horizontal sections to prevent condensation from flowing back into the motor. • The minimum required number of bends.
SERVICING OF REMOTE MOTORS The installation and fitting of the external or in-roof motor should be done in such a way that will allow the unit to be removed if service is required. Additional costs incurred in the removal, such as damage to walls and roofs, are not covered under warranty. The external and in-roof motors unit should be checked regularly to ensure that nothing is obstructing the air flow from the housing.
PART 1: HOOD INSTALLATION GUIDE - INTEGRATED HOODS - ON BOARD MOTOR ON BOARD HOOD Models include SIENA F3SN60S1, F3SN90S1 and F3SND90S1 WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, PR KITCHEN & WASHROOM SYSTEMS PTY LTD RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. FOR BUILDING PURPOSES THE UNIT SHOULD BE PROVIDED TO THE CABINET MAKER / BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.
PART 1: HOOD INSTALLATION GUIDE - INTEGRATED HOODS - ON BOARD MOTOR STEP 4: The returns on the main body are now exposed. These are used to fix the main body on to the cabinetry. Place the hood in the cabinet in the level position ensuring that the controls and display will be visible when standing in front of the unit. Using the pre-drilled mounting holes, screw the hood into position. STEP 5: Once the main body is secure into the cabinetry the stainless steel fascia can then be slid inside the main body.
1 2 600650mm 3 1 2 4 3 4 3
6 5 2 2 7 1 8 1 2 3
SIENA 60 / 90 13 kg All measurements in mm 150 280 87 505 / 815 560 / 870 10 331 247 250 512 / 822 HOLE MEASUREMENTS FOR INSTALLATION
4*&/" %&&1 13 kg "MM NFBTVSFNFOUT JO NN 326 804 870 10 321 150 330 814 HOLE MEASUREMENTS FOR INSTALLATION
PART 1: HOOD INSTALLATION GUIDE - INTEGRATED HOODS - REMOTE MOTOR INTEGRATED HOOD Models include MILANO F3ML60S1, F3ML90S1, F3MLD90S1, F3MLD12S1 and GENOVAF3GV12S1 WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, PR KITCHEN & WASHROOM SYSTEMS PTY LTD RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. FOR BUILDING PURPOSES THE UNIT SHOULD BE PROVIDED TO THE CABINET MAKER / BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.
PART 1: HOOD INSTALLATION GUIDE - INTEGRATED HOODS - REMOTE MOTOR STEP 6: Connect the hood outlet to the 200 mm flexi ducting leading to the in-roof or external motor. STEP 7: Attach the male plug of the rangehood unit to the main power supply. Note to electricians: Standard 10 amp general power outlet (GPO) required. Position GPO as close to the hood unit as possible. STEP 8: Connect the female power socket of the rangehood to the male plug from the remote motor .
1 2 600650mm 3 1 2 4 3 4
6 5 2 2 7 1 8 1 2 3
MILANO 13 kg "MM NFBTVSFNFOUT JO NN 200 280 117 10 331 24 HOLE MEASUREMENTS FOR INSTALLATION
MILANO 90 / 120 %&&1 13 kg "MM NFBTVSFNFOUT JO NN 200 380 117 804 / 1094 870 / 1160 10 321 326 330 814 / 1104 HOLE MEASUREMENTS FOR INSTALLATION
PART 1: HOOD INSTALLATION GUIDE - WALL HUNG WALL HUNG CANOPY Models include LATINA F5LT90S1, TREVISO F5TV90S1, ROMA F5RM90B1, MODENA F5ME12S1 and TRENTO F5TN12S1 WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, PR KITCHEN & WASHROOM SYSTEMS PTY LTD RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. FOR BUILDING PURPOSES THE UNIT SHOULD BE PROVIDED TO THE CABINET MAKER / BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.
PART 1: HOOD INSTALLATION GUIDE - WALL HUNG STEP 7: Insert the flue extension into the main flue cover. Fasten to the hood body using the screws provided (V5). Slide the extension until it reaches the desired height. STEP 8: Place the white flue bracket on the wall, verify the horizontal alignment with a spirit level and mark the 2 drilling points at the ends. STEP 9: Drill, insert 2 ø 6mm expansion plugs and fasten bracket with the relative screws (V4).
PART 1: HOOD INSTALLATION GUIDE - WALL HUNG 7 11 8 (x2) 9 ø6 ø 6 mm ø6 V4 (x2)
PART 1: HOOD INSTALLATION GUIDE - ISLAND CANOPIES - REMOTE MOTOR ISLAND HUNG CANOPY Models include TREVISO F7TV90S1, ROMA F7RM90S1 and TRENTO F7TN12S1 WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, PR KITCHEN & WASHROOM SYSTEMS PTY LTD RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. FOR BUILDING PURPOSES THE UNIT SHOULD BE PROVIDED TO THE CABINET MAKER / BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.
PART 1: HOOD INSTALLATION GUIDE - ISLAND CANOPIES - REMOTE MOTOR STEP 3 2 2.1 Insert the extension flue into the main piece and secure at the required height with masking tap. V1 (x4) Ø8 Ø8 STEP 4: ø8 Ø8 V1 T Slide the stainless steel chimney covers up and secure to the bracket. You may need to drill some new holes through the cover and bracket to secure the chimney cover depending on desired length.
4 STEP 3 Insert the extension flue into the main piece and secure at the required height with masking tap. Slide the stainless steel chimney covers up and secure to the bracket. You may need to drill some new holes through the cover and bracket to secure the chimney cover depending on desired length. In order to avoid streaking the steel during the installation process do not remove the protective film from the upper piece until all pieces are in the correct position.
REMOTE MOTOR SOLUTIONS EXTERNAL ROOF SOLUTION 765, 1140 & 2010m3/h 440 108 17 185 1. Fan power supply connects to internal hood unit 1 2. T ile or metal roof flashing (optional accessory) 2 3 3. Rigid duct mount (optional accessory) 702 4. 2 00mm flexi ducting (attached to internal hood unit)* 60 *Advise to include gentle bend in duct run as well ensuring ducting is pulled tight and excess removed.
PART 2: MOTOR INSTALLATION GUIDE IN ROOF SOLUTION Positioning your In-Roof Unit: It is recommended that the In-Roof motor unit be mounted in a roof space or wall cavity. Please ensure that the In-Roof motor unit is positioned in an environment that is free of other gases to enable an efficient expulsion of the cooking by-products and to ensure that back draft of external gases doesn’t take place. Please ensure the motor is positioned away from other exhausts such as replace chimneys, gas fuses, etc.
PART 2: MOTOR INSTALLATION GUIDE EXTERNAL ROOF SOLUTION - METAL ROOF INSTALLATION Inspection: Ensure the unit has arrived in good condition and that the impeller will spin freely. This product is designed to be installed on a roof up to 45° pitch. 1. Installation of this product should be carried out by appropriately qualified persons. 2. Cut a hole in the roof 200 mm minimum (with regard to roof pitch angle) diameter.
PART 2: MOTOR INSTALLATION GUIDE EXTERNAL ROOF SOLUTION - TILE ROOF INSTALLATION Inspection: Ensure the unit has arrived in good condition and that the impeller will spin freely. This product is designed to be installed on a roof up to 45° pitch. 1. Installation of this product should be carried out by appropriately qualified persons. 2. Prepare an opening in the tiled roof 220 mm minimum (with regard to roof pitch angle) diameter.
PART 2: MOTOR INSTALLATION GUIDE EXTERNAL WALL SOLUTION Inspection: Ensure the unit has arrived in good condition and that the impeller will spin freely. Installation: 1. Installation of this product should be carried out by appropriately qualified persons. 2. This fan is designed for connection to 200 mm duct using duct tape or clamps. 3. Cut either a circular or square hole in the wall between 210-240 mm diameter/ square. Ensure a clean edge. 4.
EW-765 / EW-1140 SPECIFICATIONS 325 130 162.5 80 419 123 360 6.5 4 holes 298 All measurements in mm EW-2010 SPECIFICATIONS 425 170 212.5 80 518 147 450 388 All measurements in mm 6.
DESIGNER WARRANTY All FALMEC Designer range hoods and remote motors come with a 3 year parts and labour warranty. PRKS will correct, free of charge, any defects in material or workmanship for the period of 3 years, subject to the terms of our warranty stated below. This warranty will be void if a model from the designer series is used for outdoor or commercial purposes.
PROFESSIONAL WARRANTY FALMEC Professional series hoods are covered under the same 3 year parts and labour warranty as stated for the Designer series models and as such incorporates the same terms and conditions, benefits and statutory rights however the following provisions also apply: OUTDOOR USE OF PROFESSIONAL RANGEHOODS Outdoor BBQ models from the Falmec Professional series are warranted for use above barbecues and in alfresco areas with one open wall and a solid roof such as that they are not exposed
NOTES