User Manual

PART 2: MOTOR INSTALLATION GUIDE
EXTERNAL ROOF SOLUTION - TILE ROOF INSTALLATION
Inspection:
Ensure the unit has arrived in good condition and that the impeller will spin freely.
This product is designed to be installed on a roof up to 45° pitch.
1. Installation of this product should be carried out by appropriately qualified persons.
2. Prepare an opening in the tiled roof 220 mm minimum (with regard to roof pitch angle) diameter. The hole should be
positioned adjacent to a rafter or other member to facilitate the use of the mounting brackets supplied.
3. Cut a 190 mm diameter hole in the rubber roof flashing (optional accessory) for fitting over the rigid duct.
4. Slide the flashing over the rigid duct to the required position.
5. Check the fit of the duct in the cut hole. The duct must be positioned vertically.
6. If satisfactory fasten the duct to the rafter or other support using the mounting brackets (optional accessory).
7. Fit the upper edge of the flashing underneath the tile, bending over top edge to form an anti-capillary barrier.
8. Cut two tabs in the corners of the lower section and turn under tile (refer detail). Lay the lower section of the flashing over
the tiles and form a run off tray. Form to tiles as required.
9. Attach the flexi duct leading from the rangehood to the bottom of the rigid duct using the supplied duct clamps. (purchased
separately ) can be used if necessary if the duct run has been extended.
10. Connect the male power plug to the female plug connected to the rangehood. An extension lead (purchased separately )
can be used if necessary if the duct run has been extended.
Safety Considerations:
1. All connections must be in accordance with any local regulations.
2. Fans have automatic thermal cut out switches incorporated in the motor as standard.
3. This product is not intended for use by persons (including children) with reduced sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the product.
4. For duct or partition mount, precautions must be taken to avoid the back-flow of gases into the room from the open flue of
gas or other open-fire appliances.
5. If the supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
FLEXIBLE DUCT
FIT GROMMET
SUPPLIED
FIT MOUNTING
BRACKETS
TILE FLASHING
SOAKER RUN-OFF
POWER CABLE
ø440
ø200 DUCT
ANTI-C
APILLARY
FOLD
950
150