Installation Guide
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical wiring
licensed electrician.
NOTE: If fan or supply wires are different colors than indicated,
▲
WARNING
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. (Figure 1)
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
Figure 2
Figure 1
Figure 3
Figure 4
knowledge or experience, have your fan installed by a
10
6. The wires should be spread apart with the grounded
conductor and the equipment-grounding conductor on
one side of the outlet box and the ungrounded
conductor on the other side of the outlet box.
1. Run the black, white and green wires through the
wiring hole in the side of the hanger bracket to allow for
electrical connections.
2. Connect the green grounding wire from the fan and
hanger bracket to the grounding wire from the outlet box
(this may be a bare wire or a wire with green insulation).
Securely connect these wires with wire connector
supplied with your fan.
3. Securely connect the white wire from the fan motor
to the white supply (neutral) wire using wire connector
supplied. (Figure 2)
4. Securely connect the black fan motor wire to the
black supply wire using wire connector supplied.
(Figure 2)
5. After connections have been made, turn leads
upward and carefully push leads into the outlet box,
with the white and green leads to one side of the box
and the black leads towards the other side.
120 VAC
Supply
(User
Supplied)
Black Wire
(Hot)
White
(Neutral)
Green Wire
(Ground)
(To/From
hanger
bracket
and fan)
▲
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire.
Hanger Bracket
Assembly
Wiring Wall Control (Figure 3):
Installing Wall control (Figure 4):
• With electrical power still disconnected, remove the
existing wall plate and switch.
• Make wiring connections with wire nuts as shown in
Figure 3.
– One black wire from wall control unit to black
(hot supply).
– One black wire from wall control unit to black wire
leading to ceiling outlet box.
– One green wire from wall control unit to ground wire
leading to ceiling outlet box.
MAIN FUSE BOX
• Attach wall control unit to outlet box using the two
6-32 screws provided.
• Attach face plate to the switch control.
WH-TO MOTOR
BLK-TO MOTOR
TO HOT
BLK TO FAN
GRN
TO GROUND
BLK
GRN
WH
BLK
120 VAC SUPPLY
(User Supplied)
GRN from hanger ball
GRN from bracket
Ceiling Fan