Specifications

TC-650/700
RVN2
2U Type N+1 Redundant Power Supply
Features
Universal AC input/Full range
Active power factor Correction
Protections:Over Power/Over Voltage/Short Circuits
Current Sharing design on +3.3V, +5V and +12V
Front panel LED to Indicate Power Status
Power Fault Alarm Signals
Alarm Reset
100% burn-in test
Electrical Specifications:
Model No.
TC-650/700RVN2
Input Voltage 100~240VAC,±10%
Input Frequency 47Hz ~ 63Hz
Power Factor 0.96@230VAC/50Hz,full load
Output Ratings
+5V
+3.3V
+12V
REMARKS:
Short Circuit Shut down o/p voltage, re-power on to recover
Over Voltage +5V→5.7V~6.5V,+3.3V→3.7V~4.1V,+12V→12.8V~13.9V
1A 32A 1A 32A 5% 1% 50mV
3A 46A 3A 52A 5% 1% 70mV
1A 25A 1A 25A 5% 1% 50mV
1.Total Max output of +5V AND +3.3V not exceed 200W
2.Power module Total output power not exceed 650W for
TC-650RVN2 and 700W for TC-700RVN2.
3.Noise bandwidth is from DC to 20MHz.
-12V 0A 1A 0A 1A 5% 1% 70mV
Output
Voltage
Output Current
Min. Max. Min. Max.
+5VSB 0.1A 3A 0.1A 3A 5% 1% 50mV
Protections
Efficiency 72% Typical at full load
Hold up Time 16m sec. minimum, at full load
Over Power 110% ~ 150% rated output power
Function
Operating Temperature 0°C to 45°C
Power Good Signal 100ms~500ms, TTL compatible signal
Power Fail Delay 1msec. ,TTL compatible signal
PS-ON Power off:PS-ON = 2V min. ;Power on:PS-ON = 0.8V max.
Environmental
Storage Temperature -20°C to +70°C
Operating Humidity 20% to 90%,non-condensing
Storage Humidity 5% to 95%, non-condensing
Safety & EMI/RFI
Others
MTBF 100,000 hours
Coolings 38x38x28mmx4 DC FANS
Safety Standards UL,cUL,TUV,CB
EMI/RFI Standards CISPR22(EN55022) Class B, FCC Part15 Class B
Harmonic EN61000-3-2
Dimension(DxWxH) 300x101x84mm
Input Current 12A For 115VAC, 6A For 230VAC
TC-650RVN2 TC-700RVN2
Regulation
LOAD LINE
Output Ripple &
Noise Max.(p-p)
Input Ratings

Summary of content (2 pages)