ATMO Spec Sheet
Specification Sheet
Item #: 463949
Rev Date: 2021-06-08
Fantech's side port connection HRV for budget conscious house projects,
the ATMO 150H unit brings a continuous supply of fresh air into a home
while exhausting an equal amount of contaminated air. During winter,
fresh incoming air is tempered by the heat that is transferred from the
outgoing air so you save on energy costs, while during summer, the
incoming air is pre-cooled if the house is equipped with an air cooling
system. The ATMO 150H is equipped with automatic defrost
mechanisms so you can use your HRV all year long.
Features
• Compact design
• Fans with backward curved blade
• Electrostatic filters (washable)
• Polypropylene heat recovery core
• Removable screw terminal for easy connection with external access
• Lighweight 44 lbs (20Kg)
• Multiple speed operation
Optional Controls
• ECO-Touch™ – Programmable Touch Screen Wall Control
• ECO-Feel™ – Automatic IAQ Control
• EDF7 – Electronic multi-function dehumidistat
• EDF1 – Multi-function control
• RTS-W – Wireless 20/40/60 minute timer
• RTS5 – 20/40/60 minute over-ride
• RTS2 – 20 minute over-ride
• MDEH1 – Dehumidistat
Specifications
• Duct size – 6" (152 mm)
• Voltage/Phase – 120/1
• Power rated – 168 W
• Amp – 1.4 A
• Average airflow – 162 cfm (76 L/s)
@ 0.4" P
s
(100Pa)
Fans
Two (2) factory-balanced fans with backward curved blades. Motors come
with permanently lubricated, sealed ball-bearings to guarantee long life
and maintenance-free operation.
Heat Recovery Core
Polypropylene heat recovery core covered by a limited lifetime warranty.
Core dimensions are 12” x 12” (305 x 305 mm) with a 10” (254 mm)
depth. Our heat exchangers are designed and manufactured to withstand
extreme temperature variations.
Defrost
A preset defrost sequence is activated at an outdoor air temperature of
23°F (-5°C) and lower. During the defrost sequence, the supply blower
shuts down & the exhaust blower switches into high speed to maximize
the effectiveness of the defrost strategy. The unit then returns to normal
operation, and continues cycle.
Serviceability
Core, filters, fans and drain pan can be easily accessed through latched
door. Core conveniently slides out on our new easy glide core guides. 17"
(432 mm) of clearance is recommended for removal of core.
Case
22 gauge galvanized steel corrosion resistant.
Insulation
Cabinet is fully insulated with 3/4” (19 mm) high density expanded
polystyrene.
Filters
Two (2) washable electrostatic panel type air filters 10” (254 mm) x
11.9” (302 mm) x 0.125” (3 mm).
Controls
External three (3) position (Low/Stand By/Medium) rocker switch that will
offer continuous ventilation. Fantech offers a variety of external controls.
(see controls)
Installation
Unit is typically hung by using installation kit supplied with unit. Mount-
ing chains inserted on hooks located on top four (4) corners of unit. An
optional wall bracket is available.
Warranty
Limited lifetime on polypropylene core, 7 year on motors, and 5 year on
parts.
ATMO 150H
Fresh Air Appliance (Energy Recovery Ventilator)
Product #: 463888
™