Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Figure 8
Cambio de la batería
Desconecte la toma de corriente antes de limpiar.
No seguir estas instrucciones podría provocar incendios, descargas eléctricas, e incluso la
muerte.
Desconecte el deshumidificador de la toma de corriente. El indicador de horas de operación utiliza una
batería para que pueda ser operativo si el aparato no está enchufado y se presiona el botón de horas. Para
cambiar esta batería, tendrá que desatornillar los cuatro (4) tornillos del panel de instrumentos. Desconecte
la batería agotada y sustitúyala por una nueva. Vuelva a colocar el panel de instrumentos y los tornillos, sin
apretarlos en exceso.Limpieza
Desconecte la toma de corriente antes de limpiar.
No seguir estas instrucciones podría provocar incendios, descargas eléctricas, e incluso la
muerte.
Limpieza del exterior
Utilice una solución de jabón suave, no abrasivo ni inflamable y agua limpia para limpiar el
deshumidificador. Pase un trapo para secarlo.
Limpieza del interior
Desconecte el deshumidificador de la toma de corriente.
Limpieza ligera: Saque el aire del filtro y rocíe el serpentín evaporador con agua.
Limpieza profunda: Desatornille los dos tornillos de la parte superior de la cubierta frontal. Abra la
cubierta. Rocíe los serpentines con agua. Cierre la cubierta y vuelva a colocar los tornillos
(figura 8).
Debe tenerse cuidado de no dañar láminas de la bobina, ya que las láminas dañadas pueden
restringir el flujo del aire y reducir la capacidad de la unidad para producir agua.
Almacenamiento
Las temperaturas bajo cero y el crecimiento biológico deben considerarse antes de almacenar el
deshumidificador. Para evitar el crecimiento biológico, rocíe un limpiador de evaporador sobre las
bobinas y enjuague hacia el sistema de drenaje. También debe purgar el exceso de líquido de la
bomba usando la función de purga manual para evitar problemas en ambientes de almacenamiento
bajo cero.