Specification Sheet
Specification Sheet
Item #445634
Rev Date: 2022-03-03
FIT 70E
Fresh Air Appliance
Product #: 463400
Fantech’s newest addition to the FIT series is the smallest and most
compact ERV with a profile of only 18.5” x 19.5” and 9.75" high, the FIT
70E is ideally suited for small condos and apartments that have no
mechanical room and where it must be located over a false ceiling. The FIT
70E brings a continuous supply of fresh air into a home while exhausting
an equal amount of contaminated air. The energy recovery core at the
center of the unit transfers both heat and moisture from the incoming air
to the outgoing air that was cooled and dried by the building's air
conditioner.
Features
• Compact design, only 10.4" (264 mm) installed depth
• No drain required
• Easy to install on ceiling or wall with mounting bracket included
• Energy recovery core
• Electrostatic filters (washable)
• Removable screw terminal for easy connection with external access
• Multiple speed operation
• Light weight, only 29lbs (13kg) including core
Optional Controls
• ECO-Touch IAQ – Programmable Touch Screen Wall Control
• ECO-Feel – Automatic IAQ Control
• EDF7 – Electronic multi-function dehumidistat
• EDF1 – Multi-function control
• RTS-W – Wireless 20/40/60 minute over-ride
• RTS5 – 20/40/60 minute over-ride
• RTS2 – 20 minute over-ride
• MDEH1 – Dehumidistat
Specifications
• Duct size – 4" (100 mm) round
• Voltage/Phase – 120/1
• Rated power – 58 W
• Running amperage – 0.6 A
• CSA rated amperage – 1.1 A
• Average airflow – 70 cfm (50 L/s)@ 0.4" Ps (100Pa)
Fans
Two (2) factory-balanced fans with backward curved blades. Motors come
with permanently lubricated, sealed ball-bearings to guarantee long life
and maintenance-free operation.
Energy Recovery Core
AHRI certified core made from water vapor transport durable polymer
membrane that is highly permeable to humidity. The ERV core is freeze
tolerant and water washable. Core dimensions are 8.5” x 8.5” (216 x 216
mm) with a 8” (205 mm) depth.
Frost Prevention
A preset frost prevention sequence is activated at an outdoor air
temperature of 14°F (-10°C) and lower. During the frost prevention
sequence, the supply blower shuts down and the exhaust blower switches
into high speed to maximize the effectiveness of the frost prevention
strategy. The unit then returns to normal operation, and continues cycle.
Serviceability
Core, lters, fans and electrical panel can be accessed easily from the
access panel. Core conveniently slides out with only 8” (205 mm) clearance.
Duct Connections
4" (100mm round metal duct connections with rubberized seal
Case
22 gauge G90 galvanized corrosion resistant steel case (pre-painted
door).
Insulation
Insulated with 1 in. (25 mm) of high density polystyrene.
Filters
Two (2) washable electrostatic panel type air filters 8.5" (216mm) x 8"
(205mm) x 0.125" (3mm).
Installation
Unit is typically hung by using ceiling bracket supplied with unit. Optional
chain kit available.
Warranty
5 years on energy recovery core, 7 year on motors, and 5 year on parts.
®