Makeup Air Systems What goes out, must come in
| Makeup Air Systems MUAS Makeup Air System Why do we need makeup air? In a nutshell - we would otherwise have problems. Today's homes are built to be more energy-efficient. "Tighter" construction resists the infiltration of outdoor air through the home's exterior, which limits the amount of makeup air the home will permit. Of course, you can only exhaust out from the home as much air as is able to come back in.
Makeup Air Systems | 3 The Fantech Makeup Air System is the only solution A home builder could actually satisfy a home's makeup air requirement by leaving a relatively large hole (or several) in the exterior wall. Although, a hole in the wall might satisfy the makeup air requirement in the code, most would agree that such a solution is hardly ideal, especially during peak seasonal weather conditions. The "passive" solution is similar to the hole in the wall.
| Makeup Air Systems Makeup Air System Ducted Components Duct Silencer Provides ducted sound attenuation between makeup air fan and the location of makeup air delivery to the home. Makeup Air Fan EC motor-driven fan is automatically speed-controlled by the makeup air system controller. Fast Clamp Lined with neoprene to give a vibration-absorbing, tight fit.
Makeup Air Systems | 5 Beginning in 2009 the International Residential Code® (IRC®), used in the US has included a kitchen makeup air requirement. A paragraph in chapter 15 of both the 2009 and the 2012 IRC® reads: M1503.4 Makeup air required: Exhaust hood systems capable of exhausting in excess of 400 cfm shall be provided with makeup air at a rate approximately equal to the exhaust air rate.
| Makeup Air Systems The heater automatically varies its modulating heat output to deliver air at the temperature set point, even as the air flow rate and outdoor air temperature vary. 2 1 Makeup Air Heater MUAH 10/10 MUAS 1200 Makeup Air System Automatically compensates an exhaust system with fan-powered, proportionally-varying makeup air. Makeup air system in a Single Family Home A residential makeup air system needs to be both simple and effective.
Makeup Air Systems | 7 Sound attenuation silencer for circular ducts. The silencer effectively reduces noise in the duct. Silencer LD 10 7 Roof cap with damper flap closure, duct connection and screened exhaust opening. 4 3 6 FKD 10XL EC Inline Fan Powerful and speed-controllable, the FKD series is popular for remotely located kitchen exhaust system fans. RSK 10 Backdraft Damper SHL 42 Kitchen Hood Liner RC 10 Roof Cap 5 Made from commercial grade 304, 22-gauge stainless steel.
| Makeup Air Systems Choose a MUAS that fits your home Step I - Size your system Select the Makeup Air System with capacity to compensate for the maximum air flow rate of the exhaust system being served. The MUAS includes all system component items except a heater (optional accessory), wiring, duct work, insulation and electrical disconnect. To choose a heater, follow Step II.
Makeup Air Systems Outside average air temperature by zone* * NOTE: Some areas, particularly those at high elevation, might experience colder average temperatures than the map suggests.
| Makeup Air Systems Step II - Choose your heat Select the appropriate Makeup Air Heater (if any). Select heat capacity as desired or as suggested by map zone. Each Makeup Air Heater includes an electric heater and mounting clamps.
Makeup Air Systems | 11 Dimensions MUAS 750 and MUAS 1200 Ø A C B J E D H F G Model A B C D E F H (optional) G J MUAS 750 10 10 30 1/ 7 7/ 8 9 13/16 26 5/ 85 14 99 8 14 112 13/16 10 MUAS 1200 10 2 30 1/2 10 8 38 1/2 98 13/16 All dimensions are in inches.
| Makeup Air Systems Colorado Homebuilder Meets Kitchen Makeup Air Requirement with Fantech Bruce Fraser of Fraser Construction LLC knows something that many builders do not. You can have a suitably sized kitchen exhaust system and still meet the IRC M1503.4 makeup air requirement without breaking the bank. This “good-to-know” information came as a result of a major kitchen addition/ renovation that Fraser completed at a home just west of Vail, Colorado, in the upscale community of Cordillera.
Makeup Air Systems | 13
| Makeup Air Systems
Makeup Air Systems | 15 Abiding by Code in the Pacific Northwest with Fantech’s Makeup Air System Some mechanical contractors are willing to sidestep a few building codes in order to keep a builder happy and on budget. Bob’s Heating and Air Conditioning, the Washington state contractor, is not one of them, especially when comes to safety. That’s why Doug Quinn, General Manager of Bob’s Heating makes a point of meeting the IRC M1503.4 code for makeup air, even though it hasn’t always been easy.
Customer Support: Canada 800.565.3548 CANADAsupport@fantech.net USA 800.747.1762 USsupport@fantech.net Send Orders: Canada 877.747.8116 CANADAorders@fantech.net USA 800.487.9915 USorders@fantech.net Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position. The application rendering presented in this brochure is for visual presentation purposes only.