Instructions / Assembly

3
fantech
DIMENSIONS
A
B
C
D
Model/Modèle A B C D
Rn1 4
15
/
32
(114) 10 (254) 1
1
/
4
(32) 9
1
/
4
(235)
Rn2 4
15
/
32
(114) 10 (254) 1
1
/
4
(32) 9
1
/
4
(235)
Rn2X 5
7
/
8
(149) 11
1
/
2
(292) 1
1
/
4
(32) 9
1
/
4
(235)
Rn3 5
7
/
8
(149) 11
1
/
2
(292) 1
1
/
4
(32) 9
1
/
4
(235)
INSTALLATION
The Rn1, Rn2, Rn2X, and Rn3 are designed for use with 3" and 4" sched-
ule 40 PVC pipe, when appropriate LDVI coupling is used.
Prior to installation, the suction pipe should be terminated at the exterior
wall. The suction pipe should be installed with slight incline to drain water
from the fan.
DO NOT connect fan directly to building structure
WIRING DIAGRAM
There are typically three wires to be connected to an electrical fan;
Load, Neutral and Ground. Load provides power to the fan, Neutral is
for returning current and closing the electrical circuit, and Ground is
for an additional path to safely return current to the ground, in case of
an accidental electrical short in the fan and/or discharging of fan metal
components.
Fantech radon fans are permanently connected appliances employing
a reinforced polymeric construction. The non-conductive construction
functions as a “Double Insulated” protective System (Complies with
Standard for Double Insulation Systems for Use in Electrical Equipment,
UL 1097), thus eliminating the need for a grounding conductor. All
Fantech radon fans are tested and reviewed by Underwriter Laboratories,
a 3rd party independent safety governing body, and deemed suitable for
outdoor use (Standard for Safety-Electric Fans, UL 507).
Please contact Fantech Technical Support if additional information is
needed regarding this matter.
CFM @ Static Pressure
Voltage Max Amp Max Watts Phase RPM CFM/Watts Energy Star 0.00 0.20 0.50 1.00 1.50 2.00 Max
Rn1 120 0.17 19.7 1 3100 7.30 Yes 160 130 80 - - - 0.89
Rn2 120 0.48 58.0 1 2700 2.59 No 160 150 120 80 40 - 1.97
Rn2X 120 0.61 69.0 1 2541 4.00 Yes 316 280 216 120 34 - 1.70
Rn3 120 1.20 141.2 1 2700 2.42 No 370 340 280 180 120 50 2.36
Radon fans are to be installed in the vertical orientation ONLY.
Rn2 Only
Motor
Leads
Supply
Voltage
Brown
Black
Capacitor
L (Black)
N (White)
Blue
Rn2X Only
Capacitor
Blue
Black
Brown
Motor
Leads
Supply
Voltage
L (Black)
N (White)