User Guide

3
fantech
DIMENSIONS
A
B
C
D
Model/Modèle A B C D
Rn1 4
15
/
32
(114) 10 (254) 1
1
/
4
(32) 9
1
/
4
(235)
Rn2 4
15
/
32
(114) 10 (254) 1
1
/
4
(32) 9
1
/
4
(235)
Rn3 5
7
/
8
(149) 11
1
/
2
(292) 1
1
/
4
(32) 9
1
/
4
(235)
Dimensions in inches (mm).
Dimensions en pouces (mm)
INSTALLATION
The Rn1, Rn2, Rn3, Rn4-3 and Rn4-4 are designed for use with 4"
schedule 40 PVC pipe.
Prior to installation, the suction pipe should be terminated at the exterior
wall. The suction pipe should be installed with slight incline to drain water
from the fan.
DO NOT connect fan directly to building structure
Motor
Leads
Brown
Black
Capacitor
L (Black)
N (White)
Supply
V
oltage
Blue
WIRING DIAGRAM
For models Rn1, Rn2 and Rn3 only
Rn4-3 and Rn4-4 Only
120 V Supply
Motor
White
Red
Control
Yellow
Blue
Green
Green
Black or Brown
Black
Blue
Power
White
Potentiometer
0
5
10
A
B
C
D
F
G
E
For models Rn1, Rn2 and Rn3 only
For models Rn4-3 and Rn4-4 only
Model/Modèle A B C D E F G
Rn4-3 5
7
/
8
(149) 11
1
/
2
(292) 1
1
/
4
(32) 9
1
/
4
(235) 4 (102) 3
1
/
2
(89) 6 (152)
Rn4-4 5
7
/
8
(149) 11
1
/
2
(292) 1
1
/
4
(32) 9
1
/
4
(235) 4 (102) 4
1
/
2
(114) 6 (152)