SHR 1504 Brochure
Quick Selection Chart
Heat Recovery Ventilators
Energy Recovery Ventilators
Distributed locally by:
Canada
50 Kanalflakt W
ay
, Bouctouche, NB E4S 3M5
Phone: 800-565-3548; 506-743-9500
Fax: 877-747-8116; 506-743-9600
www
.fantech.net; info@fantech.net
United States
10048 Industrial Blvd., Lenexa, KS 66215
Phone: 800-747-1762; 913-752-6000
Fax: 800-487-9915; 913-752-6466
www.fantech.net; info@fantech.net
Fantech, reserves the right to modify, at any time and without notice, any or all of its products’
features, designs, components and specifications to maintain their technological leadership position.
Article#412434 IAQ0809
©2009 Fantech, Inc. All Rights Reserved.
Fantech Warranties
Fantech HRVs and ERVs carry
the following warranties:
Motor: 7 Year (Limited)
Core (Aluminum): Lifetime (Limited)
Core (Enthalpy):
5 Year (Limited)
Other Components: 5 Year (Limited)
Model
Number
SH
704
Recirculation Recirculation Recirculation Recirculation
5
6
CFM
26
L
/s
N/A
***
N/A
***
Low
V
oltage
Low
V
oltage
Low
V
oltage
Low
V
oltage
Low
V
oltage
Low
V
oltage
Low
V
oltage
Low
V
oltage
Low
V
oltage
5
6
CFM
26
L
/s
3
0-56
CFM
14-26
L
/s
5
0-149
CFM
24-70
L
/s
5
0-149
CFM
24-70
L
/s
6
0-200
CFM
28-94
L
/s
6
0-200
CFM
28-94
L
/s
6
0-200
CFM
28-94
L
/s
6
0-200
CFM
28-94
L
/s
6
5-231
CFM
31-109
L
/s
6
5-267
CFM
31-126
L
/s
Top
(
4
II
)
Top
(
4
II
)
Side
(
6
II
)
Top
(
6
II
)
Side
(
6
II
)
Top
(
6
II
)
Side
(
6
II
)
Top
(
6
II
)
Side
(
6
II
)
Side
(
8
II
)
VH
704
VHR
704
SHR
1504
VHR
1404
SHR
2004
VHR
2004
SHR
2005R
VHR
2005R
SHR
3005R
SHR
3205RD
Port Location
(size)
A
verage Installed
Range of Air Flow
D
efrost Cycle
Strategy
Control
O
ptions
D
imensions
i
n. (mm)
Effectiveness
(ASE) at 32˚F (0˚C)
House in
S
quare Feet
*
Up To 1400
S
q. Ft.
*
*
Up To 3600
S
q. Ft.
Up To 5000
S
q. Ft.
Up To5800
S
q. Ft.
Up To6600
S
q. Ft.
Model
Number
Port Location
(size)
Average Installed
Range of Air Flow
Defrost Cycle
Strategy
Control
Options
Effectiveness
(ASE) at 32˚F (0˚C)
House in
Square Feet
*
Low
Voltage
Low
Voltage
Low
Voltage
Low
Voltage
Low
Voltage
Low
Voltage
SE
704N
SER
1504
SER
1504N
SER
2004
SER
2004N
SER
3204D
SER
3204N
Up To 3200
Sq. Ft.
**
Up To1200
Sq. Ft.
Up To 4200
Sq. Ft.
Up To 6000
Sq. Ft.
C
ontinuous
E
xhaust
C
ontinuous
E
xhaust
C
ontinuous
E
xhaust
C
ontinuous
E
xhaust
C
ontinuous
E
xhaust
C
ontinuous
E
xhaust
C
ontinuous
E
xhaust
Side
(
4
II
)
1
8
7
/
16
(
468)
10
1
/
8
(258)
1
7
1
/
4
(
439)
L
W
H
2
1
1
/
2
(
546)
10
3
/
16
(259)
1
5
5
/
8
(
396)
2
1
1
/
2
(
546)
10
3
/
16
(259)
1
5
5
/
8
(
396)
2
3
1
/
2
(
596)
17
3
/
8
(441)
1
6
1
/
8
(
413)
2
3
3
/
4
(
604)
17
1
/
4
(438)
1
6
1
/
4
(
413)
2
7
7
/
8
(
707)
17
3
/
8
(441)
2
0
1
/
2
(
520)
2
8 (711)
17
1
/
4
(438)
2
0
1
/
2
(
521)
2
7
7
/
8
(
707)
17
3
/
8
(441)
2
0
1
/
2
(
520)
2
8 (711)
17
1
/
4
(438)
2
0
1
/
2
(
521)
5
0
7
/
8
(
1292)
17
3
/
8
(441)
2
2
1
/
8
(
562)
2
7
7
/
8
(
707)
25
1
/
8
(638)
2
0
1
/
2
(
520)
67
50
CFM
26
L/s
50-130
CFM
24-61
L/s
50-130
CFM
24-61
L/s
60-170
CFM
28-80
L/s
60-170
CFM
28-80
L/s
60-240
CFM
28-113
L/s
60-240
CFM
28-113
L/s
N/A
***
Continuous
Exhaust
Continuous
Exhaust
Continuous
Exhaust
Side
(4
II
)
Side
(6
II
)
Side
(6
II
)
Side
(6
II
)
Side
(6
II
)
Side
(8
II
)
Side
(8
II
)
75 76 76 75 75 76 76
Total Recovery
Efficiency
(TRE) at 95˚F (35˚C)
42 45 45 52 52 54 54
67 67
Low
V
oltage
3
0-55
CFM
14-26
L
/s
Top
(
5
II
O
val)
VHR
704R
R
ecirculation
2
1
1
/
2
(
546)
10
3
/
16
(259)
1
5
5
/
8
(
396)
69
Recirculation Recirculation
Low
V
oltage
Low
V
oltage
5
0-142
CFM
24-67
L
/s
5
0-142
CFM
24-67
L
/s
Side
(
6
II
)
Top
(
6
II
)
SHR
1505R
VHR
1405R
2
3
1
/
2
(
596)
17
3
/
8
(441)
1
7
3
/
8
(
441)
2
3
3
/
4
(
604)
17
1
/
4
(438)
1
6
1
/
4
(
413)
73 7373 73 77 77 77 77 91 77
None None None None
* Total square footage of home plus basement with 8' ceilings estimated at 1 Air Change Per Every 3 Hours. Use for rough sizing only.
** Can be used in larger homes for low level background ventilation, if bathrooms have separate dedicated exhaust fans.
***Call customer service for line volt options including dehumidistat and plug-in 24 hour timer.
Note: Before choosing a unit, always check local code requirements.
*
Total square footage of home plus basement with 8' ceilings estimated at 1 Air Change Per Every 3 Hours. Use for rough sizing only.
** Can be used in larger homes for low level background ventilation, if bathrooms have separate dedicated exhaust fans.
***Call customer service for line volt options including dehumidistat and plug-in 24 hour timer.
Note: Low speeds are estimates.
Note: Before choosing a unit, always check local code requirements.
18
7
/
16
(468)
10
1
/
8
(258)
17
1
/
4
(439)
23
1
/
2
(596)
17
3
/
8
(441)
16
1
/
8
(413)
23
1
/
2
(596)
17
3
/
8
(441)
16
1
/
8
(413)
27
7
/
8
(707)
17
3
/
8
(441)
20
1
/
2
(520)
27
7
/
8
(707)
17
3
/
8
(441)
20
1
/
2
(520)
27
7
/
8
(707)
25
3
/
8
(645)
20
1
/
2
(520)
27
7
/
8
(707)
25
3
/
8
(645)
20
1
/
2
(520)
Dimensions
in. (mm)
L
W
H