SHR 1504 Specification Sheet
Heat Recovery Ventilator
Model SHR 1504
Distributed by:
FEATURES
• Compact design
• Backward curved blade motors
• Electrostatic filters (washable)
• Aluminum heat recovery core
• External screw type dry contacts
• Improved core guide channels for easy removal of core
OPTIONAL CONTROLS
• Eco-Touch – Programmable Touch Screen Wall Control
• EDF1 – On/Off, Low, High Speed Operation
and 20 min. On/40 min. Off Cycle Timer
• RTS3 – Intermittent Bathroom Timer with Settings
for 20/40/60 Minutes of High Speed Boost
• MDEH 2 – Mechanical low voltage dehumidistat with
On/Off switch
• MDEH 1 – Mechanical low voltage dehumidistat
• RTS 2 – 15 Minute pushbutton timer
WARRANTY
• 7 year on motors
• 5 year on parts
• Lifetime on core (limited)
SPECIFICATIONS
CASE 24 gauge galvanized steel. Powder coated finish, antique
white. Insulated with 1" (25 mm) foil-faced high density
polystyrene foam to prevent condensation and meet the
requirements of the Underwriters Laboratories 94HF.
MOTORS Two (2) German-engineered, factory-balanced ebm™
motors with backward curved blades. Motors come with
permanently lubricated sealed bearings guarantee long life and
maintenance-free operation. Seven (7) year warranty.
FILTERS Two (2) Washable Electrostatic Panel Type Air Filters,
8.5" (216mm) x 15" (380mm) x 0.125" (3mm).
CORE A aluminum heat recovery core configured for an efficient
cross-flow ventilation. Core is 9" x 9" (229 x 229 mm) with a
15" (380 mm) depth. Cores are manufactured to withstand
extreme temperature variations.
CONTROLS External three (3) position (Low/Stand By/Medium)
rocker switch that will offer continuous ventilation. Fantech
offers a variety of external controls. (see optional controls)
DEFROST
A preset defrost sequence is activated at an outdoor
air temperature of 23ºF (-5ºC) and lower. During the defrost
sequence, the supply blower shuts down & the exhaust blower
switches into high speed to maximize the effectiveness of the
defrost strategy. The unit then returns to normal operation,
and continues cycle.
INSTALLATION Unit is typically hung by using installation kit
supplied with unit. Mounting bolts provided on top four (4)
corners of unit.
SERVICEABILITY Core, filters, motors and drain pan can be easily
serviced through latched access door. Core conveniently slides
out with ease on an improved railing system. Electrical box,
placed on the outside of the unit, can also be easily accessed.
Exhaust at
High Speed
Fantech, reserves the right to modify, at any time and without notice, any or all of its prducts' features,
designs, components and specications to maintain their technological leadership position.