VHR150 Spec Sheet

Specification Sheet
Item #: 427421
Rev Date: 2018-10-22
VHR 150
Heat Recovery Ventilator
Product #: 99203
One of Fantech's most popular HRV for home projects, the VHR 150 is
designed for higher static pressure applications. The unit brings a
continuous supply of fresh air into a home while exhausting an equal
amount of contaminated air. During winter, fresh incoming air is
tempered by the heat that is transferred from the outgoing air so you
save on energy costs, while during summer, the incoming air is pre-
cooled if the house is equipped with an air cooling system. The VHR 150
is equipped with automatic defrost mechanisms so you can use your HRV
all year long.
Features
Airflow up to 159 CFM (75 L/s) @ 0,4"P
s
(100 Pa)
6" (152mm) oval duct connections with integrated airflow
measurement
Compact design, only 23.75" (603 mm) wide
Fans with backward curved RadiCAL blade
Electrostatic filters (washable)
Aluminum heat recovery core
Removable screw terminal for easy connection
Easy Core Guide Channels For Removing Core
Only weighs 45 lbs (20Kg)
Optional Controls
ECO-Touch™ (#44929) Programmable Touch Screen Wall Control
EDF7 (#44883) Electronic multi-function dehumidistat
EDF1 (#40375) Multi-function control
RTS5 (#44794) 20/40/60 minute over-ride
RTS2 (#40164) 20 minute over-ride
MDEH1 (#40172) Dehumidistat
Specifications
Duct size 6" (152 mm) oval
Voltage/Phase 120/1
Power rated 156 W
Amp 1.2 A
Average airflow 159 cfm (75 L/s)
@ 0.4" P
s
(100Pa)
Fans
Two (2) factory-balanced fans with backward curved blades. Motors come
with permanently lubricated, sealed ball-bearings to guarantee long life
and maintenance-free operation.
Heat Recovery Core
Aluminum heat recovery core covered by a limited lifetime warranty. Core
dimensions are 9” x 9” (229 x 229 mm) with a 15” (381 mm) depth. Our
heat exchangers are designed and manufactured to withstand extreme
temperature variations.
Defrost
A preset defrost sequence is activated at an outdoor air temperature of
23°F (-5°C) and lower. During the defrost sequence, the supply blower
shuts down & the exhaust blower switches into high speed to maximize
the effectiveness of the defrost strategy. The unit then returns to normal
operation, and continues cycle.
Serviceability
Core, filters, fans, drain pan and electrical panel can be accessed easily
from the access panel. Core conveniently slides out with only 17” (432
mm) clearance.
Case
24 gauge galvanized steel. Baked powder coated paint.
Insulation
Cabinet is fully insulated with 1” (25 mm) foil-face high density expanded
polystyrene.
Filters
Two (2) washable electrostatic panel type air filters 8.5” (216mm) x 15”
(380 mm) x 0.125” (3mm).
Controls
External three (3) position (Low/Stand By/Medium) rocker switch that will
offer continuous ventilation. Fantech offers a variety of external controls.
(see controls)
Installation
Unit is typically hung by using installation kit supplied with unit. Mounting
bolts provided on top four (4) corners of unit.
Warranty
Limited lifetime on aluminum core, 7 year on motors, and 5 year on
parts.

Summary of content (2 pages)