Manual

p19
Fast & Fluid Management - SK450
Error codes
Error
Cause
Action
E01
Clamping motor power too low or bad electric
wiring
Call service
E02
Preset minimal clamping pressure not reached
Call service
E03
Door opened during mixing or door switch
defective
Keep door closed during mixing. If persistent,
call service
E04 - E06
SK450 Mainboard 5V or 12V circuitry overload
Call service
E07
Clamping plate reached minimal position
Place (taller) can
E08
Can shrunk during mixing
Use less fragile can
E09
Component overload
Call service
E10
No pulses received from encoder
Call service
E12
T5 (turbo FET) of 100V power supply
defective
Call service
E18
Clamping plate risen or loosened during
mixing
Check can position
E20 - E33
SK450 Mainboard component overheat (> 90°
Celsius)
Pause for cooling, check machine ventilation.
If persistent, call service
E41
EEPROM read error
Allow reset to default settings. If persistent,
call service
E71
SK450 Mainboard defective (T7 of T10)
Call service
E89
SK450 Mainboard defective (T8 of T9)
Call service
E99
Shake motor or wiring short circuit
Call service
E100
SK450 Mainboard defective (main motor
power feed)
Call service
E101
Power supply from wall socket too high
Check mains. If persistent, call service
E102
Power supply from wall socket too low
Check mains. If persistent, call service