How to Guide

DECK RAIL POST TO RIM BOARD
FASTENMASTER TECHNICAL BULLETIN
INSTALLATION INSTRUCTIONS
1. Choose the correct length (6-1/4" or 8") and fastening
pattern for each post to rim application based on the
illustrated conditions.
2. Mark the surface of the wood with the correct pattern.
3. If a flush mounted head is required, use a 1-1/4" spade bit
to create a 1/4" deep recess in the rim or post.
4. Remove the pre-assembled ThruLOK nut from the screw and
using a 1/2" drill on low speed/high torque setting, install
the ThruLOK screw and washer into the outside face of the
application until the screw is 1/4" to 1/8" from being flush.
5. Thread the ThruLOK nut onto the exposed threaded end of
the fastener. Firmly twist on the nut by hand until snug.
6. Return to driving the screw in the
remaining 1/4" to 1/8" until the
washer and nut are firmly drawn
together.
7. Make sure that the point of the
ThruLOK fastener has passed the
“MIN LINE” printed on the nut.
8. Repeat until all of the fasteners are
installed correctly according to the
specifications contained in this bulletin.
153 BOWLES ROAD, AGAWAM, MA 01001 413
.
789
.
0252 800
.
518
.
3569 WWW.FASTENMASTER.COM
Effective July 1, 2014. Please reference our website to ensure that you are using the most up to date version.
CoNNECTIoN DETAILS
According to the current International Residential Code for One and Two-Family Dwellings, Table R301.5 guardrails and
handrails must be designed to withstand a single concentrated load of 200 pounds in any direction. A critical part of
this connection is making a strong connection between the guardrail post and the rim board of the deck. In most cases,
a 1/2" through-bolt or carriage bolt is used to make this connection. When installed as instructed in this bulletin, the
ThruLOK System can replace 1/2" bolts, meeting the 200 pound design load for this part of the connection.
deck post to single rim joist deck post to doUBle rim or
single rim WitH Blocking
APPLICATIONS