Product Manual

Modular Aluminum Compressed Air Piping
TO AIR COMPRESSOR
FILTER REGULATOR
AND
3/4" JUMPER HOSE
REQUIRED
(NOT INCLUDED)
IF YOU ARE EXPERIENCING TROUBLE WITH THIS PRODUCT,
OR MISSING PARTS, PLEASE CALL 800-954-3310 FOR ASSISTANCE
DO NOT RETURN TO STORE
INSTALLATION INSTRUCTIONS
PLANNING/LAYOUT
Before beginning the installation, create a plan as to the location of the air compressor and where you are going
to mount the compressed air outlets. On the plan locate outlets, tees and elbows.
AIR COMPRESSOR
Use a flexible jumper hose from the air compressor to the filter regulator unit to reduce vibration to the
FastPipe System.
FILTER REGULATOR
A filter regulator unit is recommended to keep contaminants
out of the air system and to allow for pressure adjustment.
PRESSURE RATINGS
The FastPipe system has a maximum working pressure of
190 psi and a temperature range from 0 to 140 deg F.
ASSEMBLY OF THREADED COMPONENTS
Apply pipe sealant/paste to all NPT pipe threaded connections
during assembly.
• Use pipe clips to secure pipe to any flat surface with mounting screw
• Ceiling or wall mount
• Clip has 5/16” thru hole and hex bore for a 5/16” hex nut
• Hex nut serves as a backer for screws
• In horizontal installations, mount clip pivot tab up
• Beam Clamp
• 5/16” threaded rod
• Pipe Clip
Example Layout
• Beam Clamp
• 3/8” threaded rod
• Loop hanger
Hangers or mounting clips should be no more than 10 ft apart and one must be at
least 6” from a fitting
Do not over tighten cantilever type tube supports, pipe must be allowed to expand
and contract slightly in length
For continuous lengths over 200 ft and change in temperature variations of 80 deg F
Consult the factory for expansion joint guidelines.
flat surface installation
hanging installation
do not use teflon tape
6” D max = 10 FT