Datasheet

Plugable Inductors (Pin Type Coils)Plugable Inductors (Pin Type Coils)
FASTRON plugable inductors offer a wide range of inductance values from 1µH to 150 000µH, a high Q and also suitable for high currents and high voltages.
They come in shielded, tube and cap versions able to protect the winding. They are available in reel packing and ammopack.
Applications
Applied in DC-DC converters and all types of electronic instruments, such as digital amplifier LPF and signal filtering applications.
Technical Data
www.fastrongroup.com
Technical Data
All dimensions in mm
Revision date : 29 Aug 2014
Core Type - Ferrite
Tolerances - J (5%), K (10%), M (20%)
Packing Code - 50 (Loose in Box) / (Tray / Box), 51 (Taped / Reel)
09P-101X-YY
Ordering Code Example:
09P - 101 X - YY
(Model) (Inductance Value) (Tolerance) (Packing Code)
09P-101K-51
Remarks : Above technical data is for non-shielded type only.
L – Value (rated inductance)
Measured with Bode 100 Vector Network Analyzer at frequency f
L
Q – Factor (min)
Measured with Bode 100 Vector Network Analyzer at frequency f
Q
SRF (min)
40 MHz measured with HP8753ES Network Analyzer
< 40 MHz measured with Bode 100 Vector Network Analyzer
DCR (max)
Measured at 25°C
Rated DC Current
I based on temperature rise, determined at the point where the temperature rise does not exceed 40°C
above the ambient temperature of 25°C
Isat Current based on inductivity drop of 10% related to the unloaded inductivity
Operating Temperature
For plugable inductors : -55°C to +85°C
For 07HCP, 07HVP, 09HCP, 09HVP : -55°C to +150°C (including component self-heating)
For 07HCP/T, 07HVP/T, 09HCP/T, 09HVP/T : -55°C to +125°C (including component self-heating)
Recommended soldering method
Wave
Moisture Sensitivity Levels (MSL)
MSL Level 1, indicating unlimited floor life at ≤ 30°C / 85% relative humidity
Solderability
Using lead free solder (Sn 99.9) at 260°C ± 5°C for 5 ± 0.5 seconds, min 90% solder coverage of
metallization
Standard: IEC 68-2-20 (Ta)
Resistance to Soldering Heat
Resistant to 260°C ± 5°C for 10 ± 1 seconds
Standard: IEC 68-2-20 (Tb)
Resistance to Solvent
Resistant to Isopropyl alcohol for 5 ± 0.5 minutes at 23°C ± 5°C
Standard: IEC 68-2-45
Climatic Test
Defined by the following standards :
IEC 68-2-1 for Cold test: -55°C for 96 hours
IEC 68-2-2 for Dry heat test: +85°C (plugable,
07HCP/T, 07HVP/T, 09HCP/T, 09HVP/T ) and
+150°C (07HCP, 07HVP, 09HCP, 09HVP) for 96 hours
IEC 60068-2-78 for Humidity test: 40°C at RH 95% for 4 days
Thermal Shock Test
Temperature cycle : For plugable, 07HCP/T, 07HVP/T,09HCP/T, 09HVP/T : -55°C to +85°C to -55°C
: For 07HCP, 07HVP, 09HCP, 09HVP : -55°C to +150°C to -55°C
Max/Min temperature duration: 15 minutes
Temperature transition duration: 5 minutes
Cycles: 25
Standard: MIL-STD-202G
Tensile Strength of Leads
(Pull Test)
Components withstand a pulling force of 10N for 10 ± 1 seconds
IEC 60068-2-21 (Ua
1
)
Mechanical Shock
Mil-Std 202 Method 213
Condition C
3 axis, 6 times, total 18 shocks
100 G, 6 ms, half-sine
Vibration
Mil-Std 202 Method 204
20 mins at 5G
10 Hz to 2000 Hz
12 cycles each of 3 orientations

Summary of content (2 pages)