Manual

RemoteControlInterfaceOperation
Thisinterfaceisfittedasstandardtoallunitsandisaccessedviathe9-pinD-typeconnectorontherearofthe
unit.Notethattoconnecttoacomputer'sCOM(serial)portcorrectly,aone-to-onecablemustbeused,and
NOTa'nullmodem'cable.A'nullmodem'cablehasthe'transmit'and'receive'wiresswappedoverandwill
notwork.
TheRS232connectionissuitablefordistancesofaboutamaximumof25feetbetweenthePCandtheunit.If
youexperienceproblemswiththeconnections,consider
·selectingaslowerbaudrate
·selectingthe'UseAcknowledgeCmd'optioninAudioCore(seetheRemoteMenu>RS232
Configurationwindow)
·runningtheunitviatheRS485interface
Notethanonlyoneunitatatimemaybeconnectedtothecomputerviathisinterface.Additionalunitsmaybe
'daisy-chained'viatheRS485connectionsfromthebackofthefirstone(itactingasaconverterforthem),but
theirRS232portsarenotused.
Atypicalinterfaceset-upmightinvolverunninganRS232linkfromlaptoporadesktopcomputertoaSP27
unitsetupasamasterunit.Thediagrambelowshowsthismethodofconnection,therequiredmenuoptions
arealsogiven.NotethattheRS232cablemustbea1-1connectiontype,NOTanullmodemcable(which
hasconnectionscrossedinternally).
RS232Connection(SingleUnit)
RS232Interface
LoadingNewSoftwareviaaPC
Theunit'sinternalsoftwaremaybeupdatedviatheRS232port,oneunitatatime.Werecommend
disconnectingallotherdeviceswhenupdatingthesoftware.
Theunit'sinterfacemustbesetasRS232MasteronID1forthePCloaderprogramtorecogniseitandallow
theupdatetobesent.
Downloadthelatestversionoftheloaderprogramandtheunitsoftwareandfollowtheinstructionsincluded
withthiszipfile.AnRSSfeedisavailableonthewebsitetoensureimmediatenotificationofsoftware
releases.